SCN60
Service
15.Remove breaker & set aside
16.Pull auger from freezer by lifting straight up (be careful as auger has sharp edges!)
Note: If auger does not lift freely, see Auger Removal Procedure.
17.Inspect auger flights for signs of wear
18.Inspect evaporator barrel for signs of radial scoring
19.Remove 4 screws securing gearbox bracket to compartment base
20.Carefully lift and rest gearbox & bracket against back of compartment lip
21.Remove four 5/32” allen head screws holding adapter to evaporator
22.Remove evaporator from gearbox
**tools
Replace gear reducer and install a new water seal.
May 2011 Page 15