Scotsman Ice SCN60 dimensions Plumbing Gravity Drain Model

Page 10

SCN60

Installation and Use

Plumbing: Gravity Drain Model

Caution: Restrictions in the drain system to the machine will cause water to back up into the ice storage bin and melt the ice. Gravity drain tubing must be vented, have no kinks and slope to the building drain. Air gaps are typically required by local code.

1.Place the ice machine in front of the installation opening. Adjust leveling legs to the approximate height.

2.Remove the upper back panel if needed for access to the drain fitting.

Note: If you are connecting a gravity drain model and the drain opening has been located in the floor under the base pan according to the pre install specifications, follow steps 3 through 5 to drain the unit through the base. If not, proceed to step 6b.

clamp. Leave the other end of the tube lying on the floor of the base pan until the unit is positioned over the floor drain.

6.Route the drain tube. Either a) Insert the drain tube through the base pan into the floor drain or b) Route the drain tube through the hole in the lower back panel and connect to barbed elbow and secure with a clamp.

7.Reinstall the upper back panel.

Water Supply

The recommended water supply tubing is ¼ inch OD copper. Stainless steel flex or reinforced PCV tube may also be used. Install an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be installed behind the

3.Remove the clamp and barbed elbow and take off the plastic cover in the base pan below the drain hose.

4.Connect a straight 5/8” barbed connector to the drain hose, securing with the clamp removed in step 3.

5.Cut an 8” piece of 5/8” ID X 7/8” OD tygon (clear plastic) tubing. Slide one end of the tube onto the outlet of the barbed connector and secure with a

Drain Tubing

Inside Cabinet

Connect

Water Supply

Here

unit.

The water connection is at the back of the cabinet. Connect using a compression fitting, one is supplied tied to the water inlet tube.

When built in: Coil enough tubing behind the machine so it can be pushed into the cavity without kinking the tubing.

May 2011 Page 10

Image 10
Contents SCN60 IntroductionProduct Description Cabinet Dimensions Installation Notes Location RecommendationsFamiliarization Decorating Features Door Panel AttachmentDoor Panel Attachment Door Swing Plumbing Pump Model Drain Pump Model drain installationDrains Water Supply Plumbing Gravity Drain Model Initial Start Up Installation check listElectrical and Start Up Ice level controlIce Making UseNoise Control PanelMaintenance Scotsman strongly recommends regularHow to remove scale from the ice making system Scoop out and discard all of the iceDrain Plug Other Maintenance BothService SCN60 serviceComponents Evaporator and Auger Control System Water System Storage Performance and Technical Specs Controller ResetLight Blink Information Electrical Sequence Safety Shut DownsOther Control Functions Service Diagnosis Problem Likely Cause Probable SolutionWith power on and Ice Making light on Compressor Component DiagnosticsMembrane Switch Pump Switch Pump model only Ice Level SensorIce Capacity Refrigerant chargeEvaporator construction Removal and ReplacementLubricants and Sealants SCN60 Gearbox Access & Removal Hazard of Electrical ShockSCN60 Water Seal Replacement Gear Reducer Replacement Ice Breaker ReplacementEvaporator Replacement Drain Pump if equipped Fan Blade or MotorCompressor replacement Bin and Cabinet Auger Motor or Motor Capacitor