Scotsman Ice SCN60 dimensions Location Recommendations, Installation Notes

Page 4

SCN60

Installation and Use

Location Recommendations:

The machine can be built into a cabinet. It is an air cooled refrigeration system and so air flows in and out of it through the grill at the bottom front. The grill must not be blocked by any covering door or other obstruction.

Drain Conversion: A gravity drain model can be converted to a drain pump model by installing a drain pump kit. The drain pump kit consists of a drain pump, wiring harness and associated tubing. The part number is A39462-021.

Installation Notes

Warm Air Out

Air Intake

Built In Situations: If a finished floor is to be installed in the area after the ice machine has been built in, shims the expected thickness of the floor should be installed under the unit to keep the machine level with the planned floor level.

Note: The water connection is at the back and adds a few inches to the cabinet depth. Minimum clearance is 0 in. at the top, 2 in. at the rear and 1/8 in. at each side.

Installations on a slab: Use a pump model and pump the water to the point of drainage. Pump models will pump 1 story (10 feet) high.

Installations over a crawl space or basement:

Either gravity drain or pump model units may be used, if there is not enough room behind the machine for a drain/waste receptacle, the drain will have to be below the floor.

Note: When installed in a corner, the door swing may be limited due to handle contact with the wall or cabinet face.

There are two models, one is a gravity drain type and it must have a building drain connection below the level of the drain tube at the back of the cabinet; the other is a pump drain model which can force drain water up a maximum of 10 feet, allowing it to be located where a gravity drain isn’t available.

Kickplate Extension: In some situations the leg levelers will be extended enough to become visible. A kit to extend the kickplate over the legs is KKPF.

Cabinet Stability: In some free standing installations it may be prudent to add a bracket that secures the back of the cabinet to a wall. That kit number is KATB.

All models require a water supply. Water supplies vary in the degree of mineral content. High mineral content water will require more frequent maintenance. Water filtration may improve the taste of the ice as well as cut down on some of the mineral build up.

May 2011

Page 4

Image 4
Contents SCN60 IntroductionProduct Description Cabinet Dimensions Installation Notes Location RecommendationsFamiliarization Decorating Features Door Panel AttachmentDoor Panel Attachment Door Swing Plumbing Pump Model Drain Pump Model drain installationDrains Water Supply Plumbing Gravity Drain Model Installation check list Electrical and Start UpInitial Start Up Ice level controlUse NoiseIce Making Control PanelMaintenance Scotsman strongly recommends regularHow to remove scale from the ice making system Scoop out and discard all of the iceDrain Plug Other Maintenance BothService SCN60 serviceComponents Evaporator and Auger Control System Water System Storage Performance and Technical Specs Controller ResetLight Blink Information Electrical Sequence Safety Shut DownsOther Control Functions Service Diagnosis Problem Likely Cause Probable SolutionWith power on and Ice Making light on Component Diagnostics Membrane Switch Pump Switch Pump model onlyCompressor Ice Level SensorIce Capacity Refrigerant chargeEvaporator construction Removal and ReplacementLubricants and Sealants SCN60 Gearbox Access & Removal Hazard of Electrical ShockSCN60 Water Seal Replacement Gear Reducer Replacement Ice Breaker ReplacementEvaporator Replacement Drain Pump if equipped Fan Blade or MotorCompressor replacement Bin and Cabinet Auger Motor or Motor Capacitor