INSTALLATION

INSTALLATION

10)Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11)Under no circumstances should this appli- ance be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

12)Installation and any repairs to this appliance should be done by an authorised service person. An authorised service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

13)Do not slam shut or strike the glass door.

14)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15)The appliance area must be kept clear and free of combustible materials, (gases and other flammable vapours and liquids).

INSTALLATION

CHECKLIST

1)Check Clearances to Combustibles (page 6), location of unit (page 6) and fluing requirements (pages 8 to 10).

2)Install Louvers, page 7.

3)Install fluing, either with the DV Stove Hor- izontal Flue Kit (page 10) or the Dura-Flue Termination kits (page 12). Set Flue Restric- tors, page 9.

4)Make gas connections, page 16. Test the pilot. Must be as per diagram.

5)If necessary, convert to LPG (page 17) or convert to lower Btu rating (page 19).

6)Test Gas Pressure, page 16.

7)Install log set, see page 19.

8)Install Front Door Front, page 21.

9)Install optional Remote Control, page 21.

10)Final check, page 21.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibil- ity of the manufacturer.

CLEARANCES TO COMBUSTIBLES

The clearances listed are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector. The farthest distance is correct if the two clearances do not coincide.

For example, if the appliance is set as indicated in one of the figures but the connector is too close, move the stove until the correct clear- ance to the connector is obtained.

This appliance may be installed only with the clearances as shown in the situations pic- tured. Do not combine clearances from one type of installation with another in order to achieve closer clearances.

This unit can be installed on a solid combustible surface like a wood floor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with unit) is installed.

Use the minimum clearances shown in the diagrams below:

FG39-NG & FG39-LPG Clearances

A Side Wall to Unit

 

 

190 mm

B Back Wall to Unit

 

 

150 mm

E Side Wall to Unit

 

 

50 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FG39-NG & FG39-LPG

Reference Dimensions

C Back Wall to Flue Centerline

11" / 280 mm

 

D Side Wall to Flue Centerline

521 mm

 

F Side Wall to Flue Centerline

280 mm

 

 

 

 

 

 

 

 

 

Minimum ceiling height is 914 mm from top of unit.

LOCATING YOUR

REGENCY GAS STOVE

When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper opera- tion.

A)Cross Corner

B)Room Divider

C)Island

D)Flat on Wall

E)Flat on Wall Corner

F)Flush with Wall/ Alcove

 

12’ (4m)

 

Max.

 

B

A

12’ (4m)

 

Max.

F

 

 

C

E

D

For Flue Termination requirements, see page 8.

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer.

This includes:

1)Clocking the appliance to ensure the correct firing rate (rate noted on label) after burning appliance for 15 minutes.

COMBUSTION AND VENTILATION AIR

The combustion air from this appliance is drawn from outside the building through the outer flue.

Extra provision for combustion air inside the room is not required.

6

Regency FG39 FireGenie Freestanding Gas Stove

Page 6