Regency FG39-LPG, FG39-NG A B C, Installer Notice, Theseinstructionsmustbeleftwith the appliance

Models: FG39-NG FG39-LPG

1 36
Download 36 pages 8.73 Kb
Page 18
Image 18
A

INSTALLATION

21)Turn on the gas supply and plug in the power cord.

22)Adjusting the Outlet Pressure

All the adjustments must be carried out in the following order:

Remove the modulator plastic cap (A) using needle nose pliers.

Maximum pressure: Turn the unit ON to its highest input rating. Screw in the nut (B) to increase the outlet pressure and screw it out to decrease it. Use a 10 mm wrench.

NOTE: The outlet pressure must be set to maximum 2.65 kPa.

Minimum pressure: Remove one of the cables connected to the electric modulator. Keeping the nut (B) blocked, screw in the screw (C) to increase the pressure and screw it out to decrease it. Use a screw- driver 6 x 1 blade.

NOTE: The outlet pressure must be set to minimum 0.74 kPa.

A

B C

23)At the end of all setting and adjustment operations, check electrical insulation and gas leaks.

24)Reverse step 20.

25)Check operation of fan and flame control.

26)Check for proper flame appearance and glow on logs.

Installer Notice:

Theseinstructionsmustbeleftwith the appliance.

Cable

Electric

Modulator

After carrying out all adjustments, block the setting screws with paint, taking care not to obstruct the breather orifice of the pressure.

Put back the modulator plastic cap.

WARNING: To ensure the correct opera- tion of the modulator it is necessary that the plastic cap (A) is returned to its original location.

18

Regency FG39 FireGenie Freestanding Gas Stove

Page 18
Image 18
Regency FG39-LPG, FG39-NG A B C, Installer Notice, Theseinstructionsmustbeleftwith the appliance, Cable Electric Modulator