Planning Your Dura-Flue

Installation

There are two basic types of Dura-Flue Room Sealed System installations: horizontal termi- nation and vertical termination. Confirm the maximum horizontal run and maximum vertical rise from the diagrams on page 9.

When planning your installation, it will be nec- essary to select the proper length of flue pipe for your particular requirements. For horizontal installations, determine the minimum clearance from the rear of the unit to the wall. It is also important to note the wall thickness. (The wall thimble is suitable for 2 x 4 or 2 x 6 / .6m x 1m or .6m x 2m wall construction.) Select the amount of vertical rise desired for "vertical-to- horizontal" type installations.

Warning: Always maintain required clear- ances (air spaces) to nearby combusti- bles to prevent a fire hazard. Do not fill air spaces with insulation.

The minimum clearance requirements between the outer wall of the flue pipe and nearby combustible surfaces is 1-1/4 inch. Be sure to check the flue termination clearance require- ments from decks, windows, soffits, gas reg- ulators, air supply inlets and public walkways as specified in the Exterior Flue Termination Locations on page 8 and in your local building codes.

Note: These are the minimum pieces required. Other parts may be re- quired for your particular instal- lation. See below for a list of flue parts.

If installing termination on a siding covered wall, a vinyl siding standoff or furring strips can be used in order to ensure that the termination is not recessed into siding.

The vinyl siding standoff is required for walls with vinyl siding.

Minimum components for a Dura-Flue Horizontal Installation:

A)Dura-Flue Horizontal Termination Kit

B)Wall Thimble (required for combus- tible walls)

Minimum components for a Dura-Flue Vertical Termination:

C)Dura-Flue Vertical Termination Kit

The Simpson Dura-Flue Room Sealed System offers a complete line of component parts for installation of both horizontal and vertical instal- lation. Many items are offered in decorative black, as well as galvanized finish. The galva- nized pipe and fittings are used for concealed

Vertical

Terminal

Storm Collar

Part # 953

locations such as attics or where corrosion is a factor, such as above the roof line. Decora- tive brass trim kits are available for both wall thimbles and ceiling support boxes.

Part # Description

971Horiz. Termination Kit includes: 90o black elbow, wall thimble cover, horiz. square termination cap, 24" black pipe, 11" -14" 5/8" adjustable

 

black pipe

970

Basic Horiz. Termination Kit

 

includes: 90o black elbow, wall

 

thimble cover, horiz. square

 

termination cap

978Vert. Termination Kit includes 0/12 - 6/12 pitch adjustable

flashing, storm collar, low profile term. cap

908B 6" (152mm) Pipe Length-Black

907B 9" (229mm) Pipe Length-Black

90612" (304mm) Pipe Length Galv.

906B 12" (304mm) Pipe Length-Black

90424" (610mm) Pipe Length Galv.

904B 24" (610mm) Pipe Length-Black

90336" (914mm) Pipe Length Galv.

903B 36" (914mm) Pipe Length-Black

90248" (1219mm) Pipe Length Galv.

902B 48" (1219mm) Pipe Length-Black

911B 11"-14 5/8" (219mm - 372mm) Adj. Pipe Length-Black

917B 17"- 24" (432mm - 610mm) Adj. Pipe Length Black

945

45O Elbow Galv.

945B

45O Elbow-Black

945G

45O Elbow-Swivel Galv.

990G

90O Elbow-Swivel Galv.

To determine the length of flue pipe required for vertical installations, measure the distance from the unit flue outlet to the ceiling, the ceiling thickness, the vertical rise in an attic or second storey, and allow for sufficient vertical height above the roof line.

For multi-storey applications, fire stops are required at each floor level. If an offset is needed, additional pipe, elbows and supports

Flashing

 

Vinyl Siding

Standoff (Optional)

943 or 943S

 

Part #950

 

Round

 

 

Ceiling Firestop

Support Box/

 

(Part # 963)

Wall Thimble

 

 

(Part # 940)

AstroCap

 

 

Round Support

 

Termination Cap

 

(Part# 946-523)

Box/Wall Thimble

 

 

 

(Part # 940)

 

Wall Thimble

 

 

 

 

Part # 942

will be required.

Do not exceed the maximum number of elbows. One 90o for horizontal terminations and two 45o for vertical termination.

DURA-FLUE FLUING

COMPONENTS

You will require the following components with your new Regency Room Sealed Freestanding Gas Stove. Please review your product to make sure you have everything you need. In the eflue that you are missing any part, contact your dealer.

Pipe Length

Adj.Pipe Length

 

11" - 14-5/8"

 

(279mm - 372mm)

 

90o Elbow

 

24" (610mm)

 

Pipe Length

Dura-Flue Basic

Horizontal Kit # 970

190o Elbow

1Wall Thimble Cover

1Astro Cap

12

Regency FG39 FireGenie Freestanding Gas Stove

Page 12
Image 12
Regency FG39-LPG, FG39-NG Dura-Flue Termination Kit, Dura-Fluefluing Components, Planning Your Dura-Flue Installation