OPERATING

OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

Before operating this appliance, proceed through the following check list.

1)Read and understand these Instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the three pieces of door glass are properly positioned. Never operate the appliance with any of the glass removed or with the door open.

5)Verify that all flueing and the cap is unob- structed.

6)Verify log placement.

RESETTING

THE UNIT

1)Open the pedestal door on the unit.

2)Press the reset button for approximately 3 seconds and release. The reset button is located on the unit's control panel.

3)Wait for approximately 3 seconds and the pilot sparks can be heard and seen. It would take 2 to 3 seconds for the flame to be lit.

SHUTDOWN

INSTRUCTIONS

1)Press the ON/OFF button once.

2)Turn off all electric power to the appliance if service is to be performed.

FAN OPERATION

Set the fan speed on the control panel located in behind the pedestal door to adjust fan to the desired speed.

Control Panel

Pressing and releasing the plus (+) FAN button will change the fan speed as follows:

OFF -> LOW -> MEDIUM -> HIGH -> OFF, etc.

Pressing and releasing the minus (-) FAN button will be the reverse of the above.

LIGHTING

INSTRUCTIONS

1)Plug the power cord into a power outlet.

2)Press and release the ON/OFF button once to start the unit.

3)After approximately 3 seconds the spark ignition system will spark for 40 seconds to light the main burner.

4)If the main burner does not light, reset the unit.

FIRST FIRE

The FIRST FIRE in your heater is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it with the fan on.

When first operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac- turing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass may require cleaning.

NOTE: The main burner will always start on "HIGH" and resume it's last setting after 20 seconds of operation.

NOTE: When the glass is cold and the appli- ance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DONOTATTEMPTTOCLEANTHEGLASS WHILE IT IS STILL HOT!

DO NOT BURN THE APPLIANCE WITH- OUTTHEGLASSFRONTINPLACE.

ADJUSTING FLAME

HEIGHT

There are six flame settings that can be adjust- ed by pressing and releasing the plus (+) and minus (-) FLAME button.

The FLAME setting button is located on the control panel in behind the pedestal door.

Regency FG39 FireGenie Freestanding Gas Stove

23

Page 23
Image 23