CONVERSION TO LOWER BTU RATING

INSTALLATION

CONVERSION TO LOWER BTU RATING

THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION

LOG SET

INSTALLATION

Read the instructions below carefully

NG Conversion Kit 730-920

Contains:

Qty. Part # Description

1904-240 Burner Orifice #37 (NG)

1918-034 Decal "Converted to 30,000 Btu"

1918-033 Instruction Sheet

LPG Conversion Kit 730-922

Contains:

Qty. Part # Description

1904-390 Burner Orifice #52 (LPG)

1918-034 Decal "Converted to 30,000 Btu"

1918-033 Instruction Sheet

Additional Piece (pkg. with unit:

1Log Bracket Restrictor

1)Shut off the gas supply.

2)Open the front door. Carefully remove the logs and lava rock.

3)Remove burner. See diagram below.

!!

6)Remove burner orifice with a 1/2" spanner and discard.

Burner Orifice

7)Reinstall new burner orifice (NG stamped #37 or LPG stamped #52) and tighten.

8)Reverse steps 3) and 2).

9)Adjust Flue restrictor setting: To set the Flue restriction as indicated in the diagram, sim- ply loosen the screws and push the flue restrictor plate to the correct position. Tight- en the screws.

Unit Btu/h

Restrictor Opening

FG3940 Mj/h

A 45mm

31 Mj/h

B 35mm

and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.

The gas log kit contains the following:

a)02-65 Rear Log

b)02-56 Middle Left Log

c)02-44 Front Left Log

d)02-46 Left Top Log

e ) 02-45 Front Right Log

f)02-47 Center Log

g)02-48 Middle Right Log

h)Embers

i)Lava

Note: Install Optional Brick Panels prior to installing logs.

Note: Use a

magnetic type screwdriver if possible.

4) Unscrew the 2 Rear LOG SETNote: Use aPosition the Log Bracket Restrictor betweenthe Rear Log Bracket and the burner.Flue Restrictorsetting at High Btu/h Log Pins and move

to the front hole po- sition.

5)Remove Rear Log Bracket and slide the

Log Bracket Re- setting at Low Btu/hThe "02" refer numbers (i.e. 02-65) aremolded into the rear of each log.Embers.EmbersManual backgroundManual background strictor between the Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Rear Log Bracket and the burner, secure with the 2 screws.

Position the Log Bracket Restrictor between

the Rear Log Bracket and the burner.

Flue Restrictor

Flue Restrictor

setting at High Btu/h

setting at Low Btu/h

10)Attach the label "This unit has been con- verted to..." on top of the data badge over the higher Btu information.

11)Check for gas leaks.

12)Check inlet and outlet pressures.

13)Check operation of flame control. Check for proper flame appearance and glow on logs.

The "02" refer numbers (i.e. 02-65) are

molded into the rear of each log.

1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.

2)Sprinkle the embers on the left and right sides of the firebox base.

Embers.Embers

Regency FG39 FireGenie Freestanding Gas Stove

19