MAINTENANCE
If your valve requires maintenance or replace- ment, follow these instructions:
NOTE: Always shut off the gas and dis- connect the power supply before removing the valve.
1)Open the front door and carefully remove the logs and lava rock.
2)Remove the burner by removing the two 1/4" hex head screws. See diagram below.
REMOVING VALVE TRAY
4)Remove the two outside frame pieces by removing two screws per side. See dia- gram below.
7)Disconnect the gas pipe line at the valve.
8)Remove the pedestal back cover by remov- ing the 4 Philips screws.
9)Disconnect the 5 pin molex connector.
10)Disconnect the ground wires.
3)Open the front pedestal door and unhook chain. You may want to put a soft cloth on the base of the unit so that when the pedestal door is open it doesn't scratch the paint. See diagram below.
5)Remove the front plate by undoing the 6
screws. | 5 Pin | Ground |
| Molex Connector | Wire |
11) Remove the 20 x 1/4" hex head screws holding the burner tray assembly in place.
12) Carefully lift the burner tray assembly out.
13) To replace the burner tray assembly, reverse these instructions.
6)Disconnect the manual switch cable and reset cables.
Manual Switch | Reset Cables |
Cable |
|
Regency FG39 FireGenie Freestanding Gas Stove | 29 |