Scotsman Ice SCN60 Component Diagnostics, Membrane Switch Pump Switch Pump model only, Compressor

Page 27

SCN60

Service

Component Diagnostics

Membrane Switch

Pump Switch - Pump model only

Unplug and check connector pins (left side is pin 1), read about 10 ohms when activating the button, and OL when not pressing the button: Pin 2-3 On/Off Switch; 4-3 Clean Reset Switch

Compressor

Check temperature of compressor, if very hot, add access valves to refrigeration system and check system pressures. If very low, add very small amount of R-134a. If pressure does not improve, capillary tube may be restricted. If pressures improve find and correct refrigerant leak.

If compressor temperature is normal and compressor is drawing high amps, check start relay.

If relay is good and compressor is not overheating but drawing high amps, replace compressor.

The pump switch activates the pump based on pressure to it from water inside the drain hose to the pump inlet. It is normally open. When pressure increases the switch closes, turning on the pump motor until the pressure falls.

The safety switch (the red one) is normally closed and operates at a higher activation pressure than the pump switch. It stops operation of the machine if it opens.

Ice Level Sensor

To operate, the unit must have:

Power to the controller

Water sensed

Call for ice

With power on and Ice Making light on, check sensor connector, if secure and the unit not operating, remove connector and jump the two middle pins at J9 on the controller together. Unit should start. If it does, replace the sensor, if not, replace the controller.

Auger

Comp

May 2011 Page 11

Image 27
Contents Introduction SCN60Product Description Cabinet Dimensions Location Recommendations Installation NotesFamiliarization Door Panel Attachment Decorating FeaturesDoor Panel Attachment Door Swing Drain Pump Model drain installation Plumbing Pump ModelDrains Water Supply Plumbing Gravity Drain Model Ice level control Installation check listElectrical and Start Up Initial Start UpControl Panel UseNoise Ice MakingScotsman strongly recommends regular MaintenanceScoop out and discard all of the ice How to remove scale from the ice making systemDrain Plug Both Other MaintenanceSCN60 service ServiceComponents Evaporator and Auger Control System Water System Storage Controller Reset Performance and Technical SpecsLight Blink Information Safety Shut Downs Electrical SequenceOther Control Functions Problem Likely Cause Probable Solution Service DiagnosisWith power on and Ice Making light on Ice Level Sensor Component DiagnosticsMembrane Switch Pump Switch Pump model only CompressorRefrigerant charge Ice CapacityRemoval and Replacement Evaporator constructionLubricants and Sealants Hazard of Electrical Shock SCN60 Gearbox Access & RemovalSCN60 Water Seal Replacement Ice Breaker Replacement Gear Reducer ReplacementEvaporator Replacement Fan Blade or Motor Drain Pump if equippedCompressor replacement Auger Motor or Motor Capacitor Bin and Cabinet