Scotsman Ice SCN60 dimensions Service Diagnosis, Problem Likely Cause Probable Solution

Page 25

SCN60

Service

Service Diagnosis

Problem

Likely Cause

Probable Solution

 

 

 

 

No power

Plug unit into power supply

 

Unit switched off

Push and release on/off button

 

 

 

 

 

Restore water supply, check sensor. If

 

 

RO water is too pure, unit cannot

 

No water, water diagnostic light is on

operate.

 

Check float valve for restriction

 

 

 

 

 

 

 

Check float valve shut off lever position

 

 

Check auger motor for voltage, if none,

 

Compressor on, fan on, auger motor not

replace controller. If there is voltage,

 

operating

check auger motor windings, if open,

 

 

replace auger motor.

 

 

Check evaporator for ice. Thaw out and

 

 

retry. Check top bearing and condition of

 

Compressor on, fan on, auger motor

auger. Replace if worn.

 

Operate unit for a short time with auger

 

cutting off on over amp safety

 

out of machine, water shut off and water

 

 

 

 

sensor bypassed. If auger motor still

 

 

overloads, replace gear reducer.

 

 

 

 

 

Check fan blade for ease of rotation,

No ice

Compressor on, auger on, fan blade not

remove any blockage and retry. Check

turning

fan motor, replace if not turning freely or

 

 

 

motor windings open.

 

 

 

 

Auger motor on, fan on, compressor not

Check compressor start relay, check

 

drawing power

compressor windings.

 

 

 

 

Auger motor on, fan on, compressor

Check compressor. See component

 

cutting off on overload

diagnostics.

 

 

 

 

Compressor on, fan on, auger motor on,

Check ice sweep. If tight to auger, auger

 

is not turning. Gears stripped, replace

 

ice sweep not turning

 

gear reducer.

 

 

 

 

 

 

 

Check connections to auger motor, if

 

Unit off on auger motor open safety

voltage to motor and it does not operate,

 

 

replace motor.

 

 

If pump model check for water back up

 

 

or open safety switch.

 

 

Check transformer, replace if not

 

Unit plugged in but no power

supplying 12 volts AC to controller.

 

Check switch membrane. See

 

 

 

 

component diagnostics.

 

 

If transformer and membrane are good,

 

 

replace controller.

 

 

 

May 2011

Page 9

Image 25
Contents Introduction SCN60Product Description Cabinet Dimensions Location Recommendations Installation NotesFamiliarization Door Panel Attachment Decorating FeaturesDoor Panel Attachment Door Swing Plumbing Pump Model Drain Pump Model drain installationDrains Water Supply Plumbing Gravity Drain Model Electrical and Start Up Installation check listInitial Start Up Ice level controlNoise UseIce Making Control PanelScotsman strongly recommends regular MaintenanceScoop out and discard all of the ice How to remove scale from the ice making systemDrain Plug Both Other MaintenanceSCN60 service ServiceComponents Evaporator and Auger Control System Water System Storage Performance and Technical Specs Controller ResetLight Blink Information Electrical Sequence Safety Shut DownsOther Control Functions Problem Likely Cause Probable Solution Service DiagnosisWith power on and Ice Making light on Membrane Switch Pump Switch Pump model only Component DiagnosticsCompressor Ice Level SensorRefrigerant charge Ice CapacityEvaporator construction Removal and ReplacementLubricants and Sealants Hazard of Electrical Shock SCN60 Gearbox Access & RemovalSCN60 Water Seal Replacement Ice Breaker Replacement Gear Reducer ReplacementEvaporator Replacement Fan Blade or Motor Drain Pump if equippedCompressor replacement Auger Motor or Motor Capacitor Bin and Cabinet