SCN60
Service
SCN60 Gearbox Access & Removal
1. | Shut off water supply | 10. Lift and remove ice chute |
|
|
2.Remove drain plug inside bin compartment
3.Disconnect power supply or unplug unit
Hazard of Electrical
Shock.
Disconnect Electrical
Power Before
Servicing.
4.Uninstall unit and pull out as needed for top and back access.
5.Remove top panel
6.Remove back panel
7.Remove ice chute/bin wall by unscrewing 2 thumb screws and lifting it out
Chute
Ice Sweep
11.Remove 4 screws securing float reservoir & set aside
12.Remove gray water tube from evaporator inlet
13.Disconnect power connection to auger motor
14.Remove 4 bolts securing breaker head to freezer by using ¼” allen wrench (socket type - best method)
8.Remove 2 orange wires from water level sensor (on top of float tank)
9.Rotate ice sweep
May 2011