SCN60
Service
Drain Pump (if equipped)
1Shut off water supply
2Remove all ice and/or any standing water.
3Disconnect power or unplug unit
4Uninstall and pull unit out to get access to left side service panel.
5Remove five screws and the service panel.
6Disconnect electrical plug to pump motor
7Disconnect drain hose from pump inlet
8Disconnect discharge hose from pump
9Remove two 3/8 inch nuts holding pump to base, lift pump up and out.
10Reverse steps to reassemble.
Fan Blade or Motor
1If equipped with drain pump follow all steps to remove pump.
2Unplug fan motor connection.
3Remove four screws holding fan motor brackets to shroud.
4Pull fan blade and motor from unit.
5If not equipped with a drain pump:
6Shut off water supply
7Remove all ice and/or any standing water.
8Disconnect power or unplug unit
9Uninstall and pull unit out to get access to left side service panel.
10Remove five screws and the service panel.
11Unplug fan motor connection.
12Remove four screws holding fan motor brackets to shroud.
13Pull fan blade and motor from unit.
11Service blade or motor and reverse to reassemble.
May 2011 Page 19