Rangemaster E6448SS, E64000 installation instructions NON-DUCTED Installation, Ducted Installation

Page 5

1. SELECT BLOWER OPTION AND INSTALLATION TYPE

1.1NON-DUCTED INSTALLATION

For a non-ducted installation, a non-duct kit ANKE60 Series (sold separately) must be installed. For maximum effectiveness, we recommend installing this kit with a single (internal) blower hood. The kit fits hoods from 30-inch width up to 48-inch width. See installation instructions included with the non-duct kit ANKE60 Series.

1.2DUCTED INSTALLATION

The Broan Elite E64000 Series range hood includes many configurations: hood with single or double internal blowers (included with the hood), or hood using external blowers. For hood using external blowers, the Broan Elite E64000 Series must be installed with in-line blower models HLB3, HLB6, HLB9 or HLB11, or exterior blower model 331H, 332H, 335 or 336 only. Other blowers cannot be substituted. (Blowers sold separately).

Plan where and how the ductwork will be installed.

If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1, 2, 3, 4, 10 and up of this manual.

Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7”, 8” or 10” round ducts, use a transition (internal blower(s) only). Use 2” duct tape to seal duct joints.

The minimum hood distance above cooktop must not be less than 24’’. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities.

Distances over 30” are at the installer and users discretion.

Roof cap

Wall cap

3¼” x 10” duct

or 7” or 8” round duct

3¼” x 10” to 7” or

3¼” x 10” to 8” transition (if using round duct)

Hood

24” minimum above

cooking surface

Wall cap

Roof cap

10” round duct

4½” x 18½” to 10” transition

Hood

24” minimum above cooking surface

HH0085A

HH0086A

SINGLE INTERNAL BLOWER

TYPICAL DUCTWORK

Exterior blower

10” round duct

Hood

24” minimum above cooking surface

HH0087A

MODEL 331H, 332H, 335 OR 336

DOUBLE INTERNAL BLOWERS

TYPICAL DUCTWORK

Roof cap

10” round duct (except HLB3, 8” round duct)

In-line blower

Wall

cap

Hood

24” minimum

above cooking

surface

HH0092A

MODEL HLB3, HLB6, HLB9 OR HLB11

EXTERIOR BLOWER

IN-LINE BLOWER TYPICAL DUCTWORK

TYPICAL DUCTWORK

 

- 5 -

Image 5
Contents Intended for Domestic Cooking only Installation InstructionsTo Reduce the Risk of a Range TOP Grease Fire ¼ X Round¼ X 10 to Adapter 4½ X 18½Model 418 10 Round E64000 Series HoodModel HLB9 800 CFM or HLB11 1100 CFM Ducted Installation NON-DUCTED Installation133⁄8 Prepare the Installation163⁄8 193⁄810¼ 578 10½ Prepare the Installation CONT’DInstall Backsplash Optional Remove the Adapter Internal Blower Hoods only Remove Filters and Grease Drip RailChoose the Openings Internal Blower Hoods only Horizontal Discharge Installation Internal Blowers onlyInternal Blower Hood only Install the Adapter and the Transition if Need beInstall the Blower Exterior or IN-LINE Blower Hood Install the Hood ALL BlowersConnect Wiring ALL Blowers Reinstall Grease Drip Rail and Filters Install Light BulbsHeat Sentry USE and CareOperation ONE Year Limited Warranty for Broan Elite Products WarrantyCooktop Lighting Halogen BlowerBroan Elite E64000 Series Wiring DiagramsInternal blower hoods Exterior or In-Line blower hoodsBroan Elite E64000 Series Exterior or In-Line blower hoods Service PartsBroan Elite E64000 Series Internal blower hoods Conçue Uniquement Pour LA Cuisson Domestique Guide D’INSTALLATIONAfin DE Réduire LES Risques DE FEU DE Cuisinière AvertissementDosseret KIT DE Recirculation Optionnel Série ANKE60Série RMP ¼ PO X 10 POOU HLB11 1100 PCM Dosseret Série RMPOU 336 1500 PCM OU 332H 900 PCMInstallation Avec Conduits Installation EN RecirculationPréparer L’INSTALLATION Installer LE Dosseret Optionnel Préparer L’INSTALLATION SuiteRetirer LES Filtres ET LA Gouttière Hotte À Ventilateurs Intérieurs Seulement Installation À Évacuation HorizontaleInstaller LE KIT DE Recirculation DE Série ANKE60 Installer L’ADAPTATEUR ET LA Transition LE CAS ÉchéantInstallation EN Recirculation Seulement Hotte À Ventilateurs Intérieurs Seulement SuiteBranchement Électrique Tous LES Ventilateurs Installer LA Hotte Tous LES VentilateursRemettre EN Place LA Gouttière ET LES Filtres À Chicane Installer LES AmpoulesHeat Sentrymc EntretienFonctionnement Garantie Fonctionnement SuiteÉclairage DE LA Surface DE Cuisson Halogène VentilateurBroan Elite Série E64000 Hottes à ventilateurs intérieurs Schémas ÉlectriquesBroan Elite Série E64000 Hottes à ventilateur extérieur ou en ligneVIS N 8 X 3/8 PO VIS N 8 X 1/2 poExclusivamente Para Cocinas Domésticas Manual DE InstalaciónPrecaución AdvertenciaConjunto DE Recirculation Serie ANKE60Placa Posterior Serie RMPHLB11 1100 PCM Placa Posterior Serie RMP12 a DE 8 aInstalación CON Tubos Instalación SIN TubosPrecaución Preparación DE LA InstalaciónInstalación DE LA Placa Posterior Opcional Preparación DE LA Instalación ContinuaciónCampanas CON Ventilador Interior Únicamente Desmontaje DEL AdaptadorVentiladores Interiores Únicamente Instalación DE LA Evacuación HorizontalInstalación DEL Conjunto DE Recirculación ANKE60 Instalación DEL Adaptador Y DEL Cambio DE SecciónVentiladores Interiores Únicamente Continuación Instalación SIN Tubos ÚnicamenteConexión DEL Cableado Todos LOS Ventiladores Instalación DE LA Campana Todos LOS VentiladoresInstalación DE LAS Bombillas Termostato Heat Sentry Utilización Y CuidadoFuncionamiento Garantía Funcionamiento SuiteIluminación DE LA Superficie DE Cocción Luces Halógenas VentiladorCampanas con ventilador exterior o en línea Campanas con ventilador interiorDe la serie E64000 de Broan Elite Filtros 11.84 X Filtros 8.84 XTornillos N DE 1/2 Iltros 8.84 X