Unified Brands HY-6E(CE) service manual To Prepare, 24 OM/SM-HY-6ECE

Page 24

3.Unplug the six terminals for the high heat elements on the heater plate. Note which wires (in the harness) go to which terminals. Both the terminals and wires are numbered I to 6.

4.Unplug the set of two pigtail wires connecting the low heat element to the heater plate.

5.Remove the two 6-32 self-tapping sheet metal screws holding the thermostat switch to the steamer table. Disconnect the two wires attached to the thermostat switch by loosening the brass screws on the switch. The switch must be removed to gain access to these screws.

6.With a socket wrench with extension, remove the four 1/2 inch nuts and lockwashers holding the heater assembly in the steam generator.

7.The heater assembly may be removed by sliding it out from the steam generator. Note that the high limit thermostat is attached to the center (No. 2) heating element.

8.Remove the gasket attached to the steam generator and throw it away. Always use a new gasket.

To Prepare:

9.Remove the high limit thermostat from the heater element by cutting the three stainless steel bands with a diagonal cutter.

10.With an open ended wrench, loosen the capillary fitting from the thermostat.

11.Apply high temperature pipe compound to the fitting and install the high limit thermostat (or replacement) fitting in the heater plate with an open ended wrench.

12.Fasten the thermostat bulb to the heater as described in Section 10.12.

To Install:

13.Install new gasket onto the four threaded studs on the steam generator.

14.Insert the entire assembly into the steam generator. There is an orientation pin so that the assembly may only be installed in the correct way. This pin is on the left of the steam generator. When properly installed, Terminals 1, 2 and 3 are on top.

15.Install the four lockwashers on each of the threaded studs. Install the four 1/2 inch nuts by hand to retain the assembly.

16.Using a socket wrench (with extension) tighten the nuts to the threaded studs.

17.Attach the high limit thermostat box to the steamer table using the two 6-32 screws.

18.Attach the six terminals of the wiring harness to the heating elements. Note that the correct wire number goes to the correct terminal. Plug in the low heat pigtail wires to the harness.

10.12Steam Generator High Limit Thermostat P/N 122009

Stainless Steel Clamp P/N 093482

1.Shut off electrical power to the steamer.

2.Remove the heating elements from the steam generator as described in Section 10.11

3.With a diagonal cutter, cut the three stainless steel bands holding the thermostat bulb to the heater element.

4.With an open ended wrench, unscrew the thermostat element from the heater plate.

To Install:

5.Apply high temperature pipe compound to the threads of the new thermostat fitting. Screw the thermostat fitting into the heater plate. Tighten with an open ended wrench.

6.Position the bulb portion of the thermostat on top of heater coil No. 2 (center heater).

7.Position the three stainless steel tie bands around BOTH the heater coil and the thermostat bulb.

NOTICE: Use only the stainless steel tie bands (Groen P/N 100968). Be careful that the thermostat bulb is in position before inserting the end of the band in the locking pod, as once it is inserted it cannot be removed.

8.Once in position, pull the tie band all the way into the locking pod. Using a needle-nose pliers hold the band where it enters the pod and turn the band to draw it tighter into the pod. Cut off the excess band with a diagonal cutter.

9.Tighten the compression nut on the heater plate using an open ended wrench.

24 OM/SM-HY-6E(CE)

Image 24
Contents HY-6ECE Hypersteam Atmospheric Convection Important Read First Important Steam can Cause Burns Table of Contents ReferencesEquipment Description Inspection and UnpackingWater Conditioning Bpst Connection on the right rear side of the steamerInstallation and Start-Up Electrical Supply ConnectionElectrical Supply Connections Water ConnectionsOperating Procedure OperationControls 10 OM/SM-HY-6ECE Cleaning Procedure Outside of SteamerSuggested Tools OM/SM-HY-6ECEIf the Service light stays on Steam Generator and Cooking ChamberMaintenance TroubleshootingParts List External Cabinet and Sheet MetalKey Description 14 OM/SM-HY-6ECECavity Control Section Steamer Base Section 16 OM/SM-HY-6ECESteamer Base Rear View Steamer Motor and Controls 18 OM/SM-HY-6ECESteamer Generator Individual Parts Key Description NewSteamer Individual Parts 20 OM/SM-HY-6ECEService Information Adjustable Legs P/NTop Right Side Panel Louvered Removal P/N 10.3 Top/Left Side Removal P/NTo Test Water Inlet Valve Three Way P/NWater Inlet Valve Coil Drain Box Spray Nozzle P/NTo Install Heater Assembly Complete with High Limit ThermostatSteam Generator P/N Steam Generator Probes High and Low Water P/NTo Prepare 24 OM/SM-HY-6ECETimer Assembly Timer Fastener Nut Control Voltage Transformer P/NElectrical Contactor Fan Motor Assembly Motor Insulation Motor Shaft Seal To Install a New Motor10.17 Fan 26 OM/SM-HY-6ECETo Install New Capacitor Motor Starting Capacitor P/NSteam Generator Ready Thermostat P/N Steam Port GasketDoor Removal/Installation/Alignment P/N Door Switch P/NDoor Reversing Procedures To AlignDoor Handle, Magnet and Block Assembly Door Gasket P/NDoor Spring P/N Door Locking Pin P/N Lock Nut P/N30 OM/SM-HY-6ECE Electrical Schematic Service Log 32 OM/SM-HY-6ECELimited Warranty To Commercial Purchasers Part Number 128717, REV. B 4/06

HY-6E(CE) specifications

Unified Brands HY-6E(CE) is a state-of-the-art cooking appliance specifically designed for professional kitchens, providing top-notch technology, efficiency, and capability. This equipment stands out due to its combination of advanced features and user-friendly controls, making it an ideal choice for restaurants, catering services, and foodservice operations.

One of the most notable features of the HY-6E(CE) is its powerful heating system, which allows for rapid cooking times and consistent results. The unit is equipped with a high-efficiency burner system that ensures even heat distribution while minimizing energy consumption. This innovative technology not only enhances cooking performance but also contributes to cost savings in energy usage.

Another significant characteristic of the HY-6E(CE) is its versatility. The appliance supports various cooking methods, including boiling, frying, steaming, and simmering, making it suitable for a wide range of culinary applications. This adaptability enables chefs to prepare multiple dishes simultaneously, thereby increasing kitchen productivity.

The design of the HY-6E(CE) emphasizes durability and ease of maintenance. Constructed from high-grade stainless steel, it is built to withstand the rigors of a busy kitchen while resisting corrosion and wear. The smooth surfaces and streamlined design facilitate quick cleaning, ensuring that hygiene standards are upheld without excessive downtime.

In terms of control and monitoring, the HY-6E(CE) features an intuitive digital interface that allows chefs to set precise temperature and timing. This level of control is crucial for maintaining culinary consistency and quality, especially in high-pressure environments. The appliance also includes safety features such as automatic shut-off and flame failure protection, ensuring a safe cooking experience.

The HY-6E(CE) is further enhanced with smart technology options that enable remote monitoring and adjustments via mobile applications. This connectivity allows operators to oversee kitchen operations from any location, optimizing workflow and ensuring that meal preparation runs smoothly.

In conclusion, the Unified Brands HY-6E(CE) is an exemplary cooking appliance that merges efficiency, versatility, and advanced technology. Its features cater to the dynamic needs of the modern kitchen, making it a valuable addition for culinary professionals who prioritize performance and reliability in their cooking operations.