5.The hose may be removed. Be careful that the hose clamps do not fall off and get lost.

IMPORTANT: Make sure that the correct part (and part number) are being used. The two hoses in the steamer are of different lengths. (See Page 17 for Part Numbers.)

To Install:

6.Slide the two hose clamps onto the hose and position the hose adjacent to the steam port and steam generator.

7.Slide the hose onto the hose nipple on the steam port and at the other end, onto the steam generator nipple. Make sure the hose is on all the way so that the end of the hose is against the face of the nipples.

8.Install the hose clamps 5/64" (2 mm) from the end of the hose.

10.23Door Removal/Installation/Alignment P/N 094150

1.To remove the door, turn off the steamer power and allow the steamer to cool. Then, remove door by supporting the weight of the door and remove hinge pin.

2.Place the door on a flat, clean table or similar support, with gasket facing up. Be careful not to scratch door surface.

3.Inspect door gasket for signs of cuts or other defects which may impair its function. Replace if necessary.

To Install:

4.To install the door, apply NEVER-SEEZ lubricant to hinge pin. Align door with hinge and insert hinge pin, or apply Locktite 242 to the door-to-hinge bolts, then install door and mounting bolts. Do NOT tighten mounting bolts at this time.

To Align:

5.Place a piece of masking tape over the door pin (bullet) hole in the door.

6.Close the door until the door pin just penetrates the masking tape. Make sure the door pin contacts only the door latch spring.

7.If door pin does not strike the center of the masking tape or spring hole in the U-channel, loosen the hinge-to-oven bolts and align the door to the door pin. Tighten hinge-to-oven mounting bolts.

8.You should be able to pull a dollar bill or comparable piece of paper smoothly between the gasket and oven cavity with the door closed. To adjust the hinge side, loosen the door-to-hinge bolts and align the door gasket with the oven cavity. Tighten the door-to-hinge mounting bolts. To adjust the bullet side refer to 10.29.

9.Operate oven in steam mode and check for leaks.

10.24Door Switch P/N 096857

1.From the right side of the steamer with panel removed, unplug the door switch from the cable harness.

2.The switch (for normal door opening) is held in place with two small 4-40 screws. With a flat blade screwdriver, remove these screws and the switch may be removed.

3.To install 4-40 screws for the door switch use a screw starter.

4.If the door has been reversed and the switch must be removed and replaced, refer to the top and left side panel removal in Section 10.3 and then remove the switch as above.

10.25Door Reversing Procedures

1.Turn off steamer power and allow steamer to cool.

2.To remove door, support door while removing hinge- to-steamer bolts.

3.Place door with hinge on a flat, clean table (or similar support), with the gasket facing up. Be careful not to scratch door surface.

4.Note and record distance between lock nut and end of door locking pin (bullet). This information will be needed during bullet installation described in Step 6.

5.Loosen lock nut with a wrench. Remove door locking pin and lock nut.

6.Coat bullet threads with NEVER-SEEZ high temperature compound. Install door locking pin and lock nut directly across steamer cavity from old door locking pin location. Install these items so that lock nut-to-end of bullet distance is approximately the same as measured in Step 4.

7.Remove the two 1/4-20 truss head screws from above and below the old bullet location and install them above and below the new bullet location.

28 OM/SM-HY-6E(CE)

Image 28
Contents HY-6ECE Hypersteam Atmospheric Convection Important Read First Important Steam can Cause Burns Table of Contents ReferencesEquipment Description Inspection and UnpackingWater Conditioning Bpst Connection on the right rear side of the steamerInstallation and Start-Up Electrical Supply ConnectionElectrical Supply Connections Water ConnectionsOperation Operating ProcedureControls 10 OM/SM-HY-6ECE Cleaning Procedure Outside of SteamerSuggested Tools OM/SM-HY-6ECEIf the Service light stays on Steam Generator and Cooking ChamberMaintenance TroubleshootingParts List External Cabinet and Sheet MetalKey Description 14 OM/SM-HY-6ECECavity Control Section Steamer Base Section 16 OM/SM-HY-6ECESteamer Base Rear View Steamer Motor and Controls 18 OM/SM-HY-6ECESteamer Generator Individual Parts Key Description NewSteamer Individual Parts 20 OM/SM-HY-6ECEService Information Adjustable Legs P/NTop Right Side Panel Louvered Removal P/N 10.3 Top/Left Side Removal P/NTo Test Water Inlet Valve Three Way P/NWater Inlet Valve Coil Drain Box Spray Nozzle P/NTo Install Heater Assembly Complete with High Limit ThermostatSteam Generator P/N Steam Generator Probes High and Low Water P/NTo Prepare 24 OM/SM-HY-6ECE Control Voltage Transformer P/N Timer Assembly Timer Fastener Nut Electrical Contactor Fan Motor Assembly Motor Insulation Motor Shaft Seal To Install a New Motor10.17 Fan 26 OM/SM-HY-6ECETo Install New Capacitor Motor Starting Capacitor P/NSteam Generator Ready Thermostat P/N Steam Port GasketDoor Removal/Installation/Alignment P/N Door Switch P/NDoor Reversing Procedures To AlignDoor Handle, Magnet and Block Assembly Door Gasket P/NDoor Locking Pin P/N Lock Nut P/N Door Spring P/N30 OM/SM-HY-6ECE Electrical Schematic Service Log 32 OM/SM-HY-6ECELimited Warranty To Commercial Purchasers Part Number 128717, REV. B 4/06