8.Remove screws and
9.Remove screws. Remove door handle from cam.
10.Apply
11.Turn handle and cam
12.Be sure door handle is in the DOWN position. Turn
13.Check operation of the cam. Push up on the door handle and check if the spring opens. If the spring does not open, cam and spring are NOT correctly aligned and problem must be corrected.
14.Apply a light amount of Locktite 242 to screws, then install screws.
15.Apply Locktite 242 to the
16.Align door to steamer. Refer to 10.23, Alignment procedure.
IMPORTANT. When the door is reversed, the alternate door switch (installed at time of manufacture) must be connected to the circuit.
17.From the right side access to the upper portion of the steamer, disconnect the two leads of the door switch.
18.In between the upper cavity and the lower cavity, the wires for the alternate door switch may be found. Connect the two wires from the switch to the wiring harness.
19.Close steamer door and operate steamer. If steamer fan does not operate, check location of door magnet and try operation again. If fan operation problem still exists, refer to the Troubleshooting Section of this Manual.
20.Allow steamer to operate for approximately 5 minutes, and then check for leaks. If there are no leaks then steamer is ready for operation. If there are
leaks around the door, recheck door alignment, and if necessary, door gasket installation.
10.26Door Gasket P/N 094147
1.To install, turn off steamer, and allow to cool.
2.Remove the door hinge using one of the following two methods:
a)Support door weight and remove hinge pin, or
b)Support weight of the door and remove the two
3.Place the door on a flat, clean, smooth table or similar support. Be careful not to scratch the door
4.Position door on workbench so that its front is lying flat, with handle hanging over edge of bench.
5.Remove inner d12oor panel.
6.Remove and discard gasket.
7.Clean back of the inner door panel. Be sure old sealant is completely removed.
8.Install new door gasket around inner door panel as shown in the illustration. Be sure the inner door panel flange is fully inserted into the door gasket groove.
9.Apply a high temperature silicone sealant, such as GE RTV 180 or equivalent, to the four door spacers.
10.Apply Locktite 242 to the inner door panel mounting screws.
11.Install inner door panel and door gasket on the door spacers, and tighten mounting screws.
12.Align door with hinge and insert hinge pin OR apply Locktite 242 to the
13.Align door to steamer.
10.27Door Handle, Magnet and Block Assembly
Door Handle | P/N 070123 |
Magnet & Block | P/N 069762 |
Screws | P/N 005764 |
Door Cam | P/N 074252 |
P/N 094144 | |
Outer Door Panel | P/N 094140 |
Inner Door Panel | P/N 094141 |