WhisperKool 5000TIR owner manual Condensation Drain Line Tube

Page 18

Condensation Drain Line Tube

The condensation drain line tube is used to remove excess condensation from the unit to a proper discharge location. It is important that the drain line tube is properly connected and used to prevent leakage and other problems associated with excess condensation.

Failure to use the condensation drain line tube will void the warranty on the unit.

Drain Line

T-Fitting

Drain Line

All units come with a drain line for additional removal of excessive condensate. It is mandatory to install the drain line attachment. During operation, the cooling unit will strip excess water from the air in order to maintain the proper level of humidity within the cellar. However in extreme humidity, additional condensate will be removed. Thus the drain line will prevent overflow and leaking by allowing for discharge of the additional condensate.

Failure to install the drain line voids warranty.

To prevent mold from growing, allow the drainline to hang above the water line.

WRONG: Drainline is under water.

Page 18

PT-EXPL5000 060311

Image 18
Contents For 5000ti 5000tiR PT-EXPL5000 Table of Contents Whisperkool Series Quick Reference Guide Quick Controller Reference Guide Standard Controller Layout XR70CXUnit Specification FAN Speed ReferenceCustomer Service IntroductionCheck the Box for the following contents Customer Warranty RegistrationReview the Packing Slip to Verify Contents Receiving & Inspecting the UnitQuick Start Guide Insulation Preparing the Wine CellarWall & Ceiling Framing Vapor BarrierMounting the Unit Exhaust Fan Air Intake Cellar WallSizing the Unit to the Room Frame the hole with two-by-four supports Installation Electrical InletsMounting Bracket Installation Applying Insulation TapeLocation of Supply and Return Grilles Placement of UnitLiquid Measuring Thermostat System Do notCondensation Drain Line Tube Drain LineInstallation Options Exterior Grille InstallationLiquid Measuring Thermostat System To Use the thermostatRemote Controller Installation and Configuration Connection wire in Side Mount configuration Multi Speed Control System Operation Standard Controller Functions XR70CX Button Normal FunctionsEnergy Reduction Alarm Codes Standard Wire Schematic XR70CX Remote Controller Functions XW260K TemperatureBlink, confirming the change in Set Point Cpsm Mode Remote Wire Schematic XW260K Maintenance Schedule Unit does not run/power up Possible Cause Solution Cellar Temperature is to Warm Possible Cause SolutionPossible Cause Solution Unit leaks water Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Compressor short cycles Possible Cause SolutionTechnical Assistance Accessories for Cooling UnitsContact WhisperKOOL Customer Service Condensate Pump KitInstallation Terms and Conditions WhisperKOOL Cooling SystemProduct Installation Requirements Installed by Date Sales and USE TAXPage Page WhisperKOOL