WhisperKool 5000TIR owner manual Liquid Measuring Thermostat System, Placement of Unit, Do not

Page 17

Placement of Unit

Slide the unit from the outside wall into your wine cellar with the outer flange flush to the wall. Secure the flange to the wall through the pre-drilled holes. The screws should penetrate the studs as well as the upper and lower supports to provide adequate support for the WhisperKOOL system (see illustration). Seal all cracks and gaps around the WhisperKOOL Extreme unit with an air-tight sealant or caulking to prevent air leakage.

Note: If you use decorative molding, it should be attached to the walls and never to the cooling unit itself.

Note: The screws to the flange should not be covered in case the unit needs to be removed for servicing.

2x4 Upper Support

Wall Stud

Mounting Flange

Back of unit

2x4 Lower Support

Drain Port

Electrical Outlet

Location of Supply and Return Grilles

Locate the supply and return grilles inside the cellar to create an airflow pattern that maximizes air circulation in the room. Avoid short circulation of the air.

Do not:

Install through-the-wall return air grilles at floor level, as they will collect dust from the floor.

Mount the unit lower than 18” from the ceiling.

Locate the supply or return air grille where it is blocked by bottles, boxes or cases.

Liquid Measuring Thermostat System

To assure a consistent temperature, place bottle probe approximately 3 feet away from the air output and not in the flow of the air.

Page 17

Image 17
Contents For 5000ti 5000tiR PT-EXPL5000 Table of Contents Whisperkool Series Quick Reference Guide Standard Controller Layout XR70CX Quick Controller Reference GuideFAN Speed Reference Unit SpecificationIntroduction Customer ServiceReview the Packing Slip to Verify Contents Customer Warranty RegistrationCheck the Box for the following contents Receiving & Inspecting the UnitQuick Start Guide Wall & Ceiling Framing Preparing the Wine CellarInsulation Vapor BarrierMounting the Unit Air Intake Cellar Wall Exhaust FanSizing the Unit to the Room Frame the hole with two-by-four supports Electrical Inlets InstallationApplying Insulation Tape Mounting Bracket InstallationLiquid Measuring Thermostat System Placement of UnitLocation of Supply and Return Grilles Do notDrain Line Condensation Drain Line TubeExterior Grille Installation Installation OptionsTo Use the thermostat Liquid Measuring Thermostat SystemRemote Controller Installation and Configuration Connection wire in Side Mount configuration Multi Speed Control System Operation Button Normal Functions Standard Controller Functions XR70CXEnergy Reduction Alarm Codes Standard Wire Schematic XR70CX Temperature Remote Controller Functions XW260KBlink, confirming the change in Set Point Cpsm Mode Remote Wire Schematic XW260K Maintenance Schedule Cellar Temperature is to Warm Possible Cause Solution Unit does not run/power up Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Unit leaks water Possible Cause SolutionPossible Cause Solution Compressor short cycles Possible Cause SolutionContact WhisperKOOL Customer Service Accessories for Cooling UnitsTechnical Assistance Condensate Pump KitWhisperKOOL Cooling System Installation Terms and ConditionsProduct Installation Requirements Sales and USE TAX Installed by DatePage Page WhisperKOOL