WhisperKool 5000TIR owner manual Energy Reduction

Page 26

Energy Reduction

1.

The ER feature can be used to save energy and aids in extending the life of the sys-

(ER)

 

tem.

 

2.

The ER button is located at the top L/H side of the control. The ER feature is acti-

 

 

vated by pressing the ER button one time, and the ER logo will appear on the digital

 

 

display.

 

3.

The purpose of the ER feature is to reduce energy cost, by shifting the Set Point up

 

 

by 4 degrees, which will allow the cooling system to run for shorter periods of time,

 

 

resulting in a reduction in energy cost.

 

4.

The ER feature allows for Energy Savings at any time - During periods of high ambi-

 

 

ent temperatures, vacations or business travel.

 

5.

To deactivate the ER feature, press the ER button one time, and the ER logo will turn

 

 

off.

 

6.

The ER feature can be conveniently adjusted to the customer’s specific needs, by

 

 

accessing the “Customer Preference Select Mode” (CPSM). See Customer Preference

 

 

Select Mode Instructions.

Set

1.

Press the “Set” button once and it will display the Set Point. After approximately 5

Button

 

seconds, the display will return to normal operation and display the Bottle Probe

 

 

temperature.

 

2.

Standard Controller - Press and hold the “Set” button for 3-5 seconds until the set

 

 

point is displayed and the °F symbol starts blinking. Next press the “UP or Down”

 

 

arrows to change the Set Point. Next press the “Set” button once and the Set Point

 

 

numbers and the °F on the display will blink to confirm the new Set Point setting.

 

3.

Press and hold the “Set” button during the display of the Hi/Low “Temperature Data

 

 

History” (hold button unit “rst” blinks on display), and it will erase the past recorded

 

 

data file and start recording, from the current time and temperature.

 

4.

Press the “Set” and the “Down Arrow” buttons simultaneously, for 10-15 seconds,

 

 

and you will access the “Customer Preference Selection Mode” (CPSM). The CPSM

 

 

allows the customer to “Fine Tune” the Control Operating System to their applicable

 

 

choice.

CPSM Mode

Press the “Set” and the “Down Arrow” buttons simultaneously, for 10-15 seconds, and

 

you will access the “Customer Preference Selection Mode” (CPSM). The CPSM allows the

 

customer to “Fine Tune” the Control Operating System to their applicable choice.

 

The following CPSM options are available for adjustment:

 

Fon – Humidity Management Enhancement: This parameter is normally set at 0, which

 

should provide adequate relative humidity for the cellar.

 

An increase in this parameter will increase the Humidity Enhancement (%RH), and a

 

 

decrease in the parameter will decrease Humidity Enhancement (%RH).

 

Adjustments should be made in increments of 5, with a maximum of 15, and a

 

 

minimum of 0.

 

After any adjustment to Humidity Enhancement, you should wait a minimum of

 

 

three days before making any additional adjustments. This will allow the cellar suf-

 

 

ficient time to acclimate to the new setting.

 

Fof - Humidity Management Enhancement: This parameter is normally set at 15. This

 

parameter should not be adjusted, as it simply provides an OFF cycle time for the fan,

 

during the compressor OFF cycle. However, the parameter is located within the CPSM

 

as a convenience to the customer, should it need to be adjusted.

 

 

 

Page 26

PT-EXPL5000 060311

Image 26
Contents For 5000ti 5000tiR PT-EXPL5000 Table of Contents Whisperkool Series Quick Reference Guide Quick Controller Reference Guide Standard Controller Layout XR70CXUnit Specification FAN Speed ReferenceCustomer Service IntroductionCheck the Box for the following contents Customer Warranty RegistrationReview the Packing Slip to Verify Contents Receiving & Inspecting the UnitQuick Start Guide Insulation Preparing the Wine CellarWall & Ceiling Framing Vapor BarrierMounting the Unit Exhaust Fan Air Intake Cellar WallSizing the Unit to the Room Frame the hole with two-by-four supports Installation Electrical InletsMounting Bracket Installation Applying Insulation TapeLocation of Supply and Return Grilles Placement of UnitLiquid Measuring Thermostat System Do notCondensation Drain Line Tube Drain LineInstallation Options Exterior Grille InstallationLiquid Measuring Thermostat System To Use the thermostatRemote Controller Installation and Configuration Connection wire in Side Mount configuration Multi Speed Control System Operation Standard Controller Functions XR70CX Button Normal FunctionsEnergy Reduction Alarm Codes Standard Wire Schematic XR70CX Remote Controller Functions XW260K TemperatureBlink, confirming the change in Set Point Cpsm Mode Remote Wire Schematic XW260K Maintenance Schedule Unit does not run/power up Possible Cause Solution Cellar Temperature is to Warm Possible Cause SolutionPossible Cause Solution Unit leaks water Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Compressor short cycles Possible Cause SolutionTechnical Assistance Accessories for Cooling UnitsContact WhisperKOOL Customer Service Condensate Pump KitInstallation Terms and Conditions WhisperKOOL Cooling SystemProduct Installation Requirements Installed by Date Sales and USE TAXPage Page WhisperKOOL