Energy Reduction | 1. | The ER feature can be used to save energy and aids in extending the life of the sys- |
(ER) |
| tem. |
| 2. | The ER button is located at the top L/H side of the control. The ER feature is acti- |
|
| vated by pressing the ER button one time, and the ER logo will appear on the digital |
|
| display. |
| 3. | The purpose of the ER feature is to reduce energy cost, by shifting the Set Point up |
|
| by 4 degrees, which will allow the cooling system to run for shorter periods of time, |
|
| resulting in a reduction in energy cost. |
| 4. | The ER feature allows for Energy Savings at any time - During periods of high ambi- |
|
| ent temperatures, vacations or business travel. |
| 5. | To deactivate the ER feature, press the ER button one time, and the ER logo will turn |
|
| off. |
| 6. | The ER feature can be conveniently adjusted to the customer’s specific needs, by |
|
| accessing the “Customer Preference Select Mode” (CPSM). See Customer Preference |
|
| Select Mode Instructions. |
Set | 1. | Press the “Set” button once and it will display the Set Point. After approximately 5 |
Button |
| seconds, the display will return to normal operation and display the Bottle Probe |
|
| temperature. |
| 2. | Standard Controller - Press and hold the “Set” button for |
|
| point is displayed and the °F symbol starts blinking. Next press the “UP or Down” |
|
| arrows to change the Set Point. Next press the “Set” button once and the Set Point |
|
| numbers and the °F on the display will blink to confirm the new Set Point setting. |
| 3. | Press and hold the “Set” button during the display of the Hi/Low “Temperature Data |
|
| History” (hold button unit “rst” blinks on display), and it will erase the past recorded |
|
| data file and start recording, from the current time and temperature. |
| 4. | Press the “Set” and the “Down Arrow” buttons simultaneously, for |
|
| and you will access the “Customer Preference Selection Mode” (CPSM). The CPSM |
|
| allows the customer to “Fine Tune” the Control Operating System to their applicable |
|
| choice. |
CPSM Mode | Press the “Set” and the “Down Arrow” buttons simultaneously, for | |
| you will access the “Customer Preference Selection Mode” (CPSM). The CPSM allows the | |
| customer to “Fine Tune” the Control Operating System to their applicable choice. | |
| The following CPSM options are available for adjustment: | |
| Fon – Humidity Management Enhancement: This parameter is normally set at 0, which | |
| should provide adequate relative humidity for the cellar. | |
| • An increase in this parameter will increase the Humidity Enhancement (%RH), and a | |
|
| decrease in the parameter will decrease Humidity Enhancement (%RH). |
| • Adjustments should be made in increments of 5, with a maximum of 15, and a | |
|
| minimum of 0. |
| • After any adjustment to Humidity Enhancement, you should wait a minimum of | |
|
| three days before making any additional adjustments. This will allow the cellar suf- |
|
| ficient time to acclimate to the new setting. |
| Fof - Humidity Management Enhancement: This parameter is normally set at 15. This | |
| parameter should not be adjusted, as it simply provides an OFF cycle time for the fan, | |
| during the compressor OFF cycle. However, the parameter is located within the CPSM | |
| as a convenience to the customer, should it need to be adjusted. | |
|
|
|
Page 26 |
|