WhisperKool 5000TIR owner manual Table of Contents

Page 3

TABLE OF CONTENTS

WhisperKOOL Extreme Series Quick Reference Guide . . . . . 4

Controller Quick Reference Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Fan Speed Reference. . . . . . . . . . . . . . . . . . . . . 6

Introduction. . . . . . . . . . . . . . . . . . . . . . . . . 7

Receiving & Inspecting The Unit. . . . . . . . . . . . . . . . 8

Quick Start Guide. . . . . . . . . . . . . . . . . . . . . . . 9

Preparing the Wine Cellar . . . . . . . . . . . . . . . . . . . 10

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Through-The-Wall Installation . . . . . . . . . . . . . . . . . 16

Installation Options . . . . . . . . . . . . . . . . . . . . . 19

Liquid Measuring Thermostat System. . . . . . . . . . . . . 20

Remote Controller . . . . . . . . . . . . . . . . . . . . . . 21

Multi Speed Control. . . . . . . . . . . . . . . . . . . . . . 23

System Operation: Standard and Remote. . . . . . . . . . . 24

Standard Control Functions . . . . . . . . . . . . . . . . . . 25

Standard Wire Schematic. . . . . . . . . . . . . . . . . . . 28

Remote Controller Functions. . . . . . . . . . . . . . . . . 29

Remote Wire Schematic. . . . . . . . . . . . . . . . . . . . 32

Maintenance Schedule. . . . . . . . . . . . . . . . . . . . 33

Troubleshooting Guide. . . . . . . . . . . . . . . . . . . . 34

Technical Assistance . . . . . . . . . . . . . . . . . . . . . 36

Accessories for Cooling Unit. . . . . . . . . . . . . . . . . . 36

Installation Terms and Conditions . . . . . . . . . . . . . . . 37

We manufacture, test and certify 100% of our wine cooling units in the USA. By sourcing the best components and closely controlling our manufacturing processes, we can assure the highest-quality, lowest defect manufacturing rates in the industry.

Page 3

Image 3
Contents For 5000ti 5000tiR PT-EXPL5000 Table of Contents Whisperkool Series Quick Reference Guide Standard Controller Layout XR70CX Quick Controller Reference GuideFAN Speed Reference Unit SpecificationIntroduction Customer ServiceReceiving & Inspecting the Unit Customer Warranty RegistrationReview the Packing Slip to Verify Contents Check the Box for the following contentsQuick Start Guide Vapor Barrier Preparing the Wine CellarWall & Ceiling Framing InsulationMounting the Unit Air Intake Cellar Wall Exhaust FanSizing the Unit to the Room Frame the hole with two-by-four supports Electrical Inlets InstallationApplying Insulation Tape Mounting Bracket InstallationDo not Placement of UnitLiquid Measuring Thermostat System Location of Supply and Return GrillesDrain Line Condensation Drain Line TubeExterior Grille Installation Installation OptionsTo Use the thermostat Liquid Measuring Thermostat SystemRemote Controller Installation and Configuration Connection wire in Side Mount configuration Multi Speed Control System Operation Button Normal Functions Standard Controller Functions XR70CXEnergy Reduction Alarm Codes Standard Wire Schematic XR70CX Temperature Remote Controller Functions XW260KBlink, confirming the change in Set Point Cpsm Mode Remote Wire Schematic XW260K Maintenance Schedule Cellar Temperature is to Warm Possible Cause Solution Unit does not run/power up Possible Cause SolutionCompressor short cycles Possible Cause Solution Unit leaks water Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Possible Cause SolutionCondensate Pump Kit Accessories for Cooling UnitsContact WhisperKOOL Customer Service Technical AssistanceWhisperKOOL Cooling System Installation Terms and ConditionsProduct Installation Requirements Sales and USE TAX Installed by DatePage Page WhisperKOOL