WhisperKool 5000TIR owner manual Alarm Codes

Page 27

CPSM

CCS – Cellar Pre-Chill Set Point: This parameter is set at 52°f, but can be adjusted to a set point

Mode

between 50°f - 67°f.

(Cont.)

 

 

CCT - Cellar Pre-Chill Duration: This parameter is set to 6 hours, but can be changed between

 

0-23.5 hours.

 

Con/Cof – Compressor On time (Con) and Off time (Cof) with a Probe 1 failure/Alarm. These

 

parameters are set at Con 40 min/Cof 10 min. In the event that there is a Probe 1 failure/Alarm,

 

the compressor/refrigeration system automatically starts a predetermined ON/OFF cycle, which

 

is controlled by the Con and the Cof parameters. The customer can adjust these parameters to

 

maintain the desired Bottle temperature.

 

Hes – Differential for Energy Reduction – This parameter is set at 4° above the set point, dur-

 

ing the Energy Reduction mode. A decrease in this setting will decrease the set point, and an

 

increase in this feature will increase the set point.

AUX

“AUX” indicates that the evaporator temperature is below 26°.

 

 

 

 

Alarm Codes

 

 

 

 

Message

Cause

 

Solution

“P1”

Bottle Probe is Unplugged

 

Attach Bottle Probe to Unit

 

 

 

Faulty Bottle Probe Connection

 

1. Check Bottle Probe attachment at circular connector

 

 

 

 

 

2. Check Bottle Probe connection at green terminal block on

 

 

 

back of controller

 

Defective Bottle Probe

 

Replace the Bottle Probe

“P2”

Faulty Evaporator Probe

 

Check Evaporator Probe connection at green terminal block on

 

Connection

 

back of controller

 

Defective Evaporator Probe

 

Replace the Evaporator Probe

“HA”

Defective Bottle Probe

 

Replace the Bottle Probe

“LA”

The Bottle Probe is sensing a

 

Allow the room to warm up which will increase the temperature

 

temperature of 4° below the set

 

of the wine

 

point

 

 

 

Defective Bottle Probe

 

Replace the Bottle Probe

“POF”

The keypad is locked

 

Hold “Up” and “Down” buttons for 3 to 5 seconds to disable,

 

 

 

“PON” should appear

Page 27

Image 27
Contents For 5000ti 5000tiR PT-EXPL5000 Table of Contents Whisperkool Series Quick Reference Guide Standard Controller Layout XR70CX Quick Controller Reference GuideFAN Speed Reference Unit SpecificationIntroduction Customer ServiceReceiving & Inspecting the Unit Customer Warranty RegistrationReview the Packing Slip to Verify Contents Check the Box for the following contentsQuick Start Guide Vapor Barrier Preparing the Wine CellarWall & Ceiling Framing InsulationMounting the Unit Air Intake Cellar Wall Exhaust FanSizing the Unit to the Room Frame the hole with two-by-four supports Electrical Inlets InstallationApplying Insulation Tape Mounting Bracket InstallationDo not Placement of UnitLiquid Measuring Thermostat System Location of Supply and Return GrillesDrain Line Condensation Drain Line TubeExterior Grille Installation Installation OptionsTo Use the thermostat Liquid Measuring Thermostat SystemRemote Controller Installation and Configuration Connection wire in Side Mount configuration Multi Speed Control System Operation Button Normal Functions Standard Controller Functions XR70CXEnergy Reduction Alarm Codes Standard Wire Schematic XR70CX Temperature Remote Controller Functions XW260KBlink, confirming the change in Set Point Cpsm Mode Remote Wire Schematic XW260K Maintenance Schedule Cellar Temperature is to Warm Possible Cause Solution Unit does not run/power up Possible Cause SolutionCompressor short cycles Possible Cause Solution Unit leaks water Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Possible Cause SolutionCondensate Pump Kit Accessories for Cooling UnitsContact WhisperKOOL Customer Service Technical AssistanceWhisperKOOL Cooling System Installation Terms and ConditionsProduct Installation Requirements Sales and USE TAX Installed by DatePage Page WhisperKOOL