WhisperKool 5000TIR owner manual Frame the hole with two-by-four supports

Page 14

Once the horizontal lines have been cut, make verti- cal cuts using the inside edge of the studs as a guide. Once you have made both vertical cuts, you should have a rectangular hole in the sheetrock. Now you have to make the same hole on the other side of the wall. Since you already have one hole, this is an easy process. Using a nail, mark all four corners of the first hole by making nail holes through the sheetrock. Then on the other side of the wall, connect the holes with a pencil mark and cut.

Sheetrock alone cannot support the weight of a

96-pound (or more) cooling system. Therefore, it is necessary to frame the hole that you have just cut with upper and lower supports.

Using two 2x4s at 14.5” in length and eight 6d nails, secure the upper and lower supports to the right and left studs, just inside the sheetrock. Make sure that the internal height remains at 16 1/4” so that the Whis- perKOOL system will fit snugly through the framed cut-out.

Frame the hole with two-by-four supports

Page 14

PT-EXPL5000 060311

Image 14
Contents For 5000ti 5000tiR PT-EXPL5000 Table of Contents Whisperkool Series Quick Reference Guide Quick Controller Reference Guide Standard Controller Layout XR70CXUnit Specification FAN Speed ReferenceCustomer Service IntroductionCheck the Box for the following contents Customer Warranty RegistrationReview the Packing Slip to Verify Contents Receiving & Inspecting the UnitQuick Start Guide Insulation Preparing the Wine CellarWall & Ceiling Framing Vapor BarrierMounting the Unit Exhaust Fan Air Intake Cellar WallSizing the Unit to the Room Frame the hole with two-by-four supports Installation Electrical InletsMounting Bracket Installation Applying Insulation TapeLocation of Supply and Return Grilles Placement of UnitLiquid Measuring Thermostat System Do notCondensation Drain Line Tube Drain LineInstallation Options Exterior Grille InstallationLiquid Measuring Thermostat System To Use the thermostatRemote Controller Installation and Configuration Connection wire in Side Mount configuration Multi Speed Control System Operation Standard Controller Functions XR70CX Button Normal FunctionsEnergy Reduction Alarm Codes Standard Wire Schematic XR70CX Remote Controller Functions XW260K TemperatureBlink, confirming the change in Set Point Cpsm Mode Remote Wire Schematic XW260K Maintenance Schedule Unit does not run/power up Possible Cause Solution Cellar Temperature is to Warm Possible Cause SolutionPossible Cause Solution Unit leaks water Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Compressor short cycles Possible Cause SolutionTechnical Assistance Accessories for Cooling UnitsContact WhisperKOOL Customer Service Condensate Pump KitInstallation Terms and Conditions WhisperKOOL Cooling SystemProduct Installation Requirements Installed by Date Sales and USE TAXPage Page WhisperKOOL