Instructions for the installer

10. ADAPTATION TO DIFFERENT TYPES OF GAS

Before carrying out the following operations, disconnect the appliance from the electricity supply.

The appliance is preset for natural gas G20 (2H) at a pressure of 20 mbar. In the case of operation with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described below.

10.1 Replacement of nozzles on the hob

1Extract the pan stands and remove all the caps and flame-spreader crowns;

2Unscrew the burner nozzles with a 7 mm socket wrench;

3Replace the burner nozzles according to the type of gas to be used (see point "10.2 Burner and nozzle characteristics table").

4Replace the burners in the correct position.

The nozzles for using city gas (G110 – 8 mbar) are available from authorised service centres.

66

Image 30
Contents Contents Precautions for use Instructions for USEInstructions for disposal Instructions for Disposal OUR Concern for the EnvironmentSafety instructions Safety InstructionsSafety instructions Instructions for the user GET to Know Your ApplianceBefore Installation Cleaning and MaintenanceUsing the HOB Gas hobPractical tips for using the burners Pan diametersGlass ceramic hob Cooking guidelinesKnob Position Suitable kind of cooking Barbeque hob Deep fat fryer Some good frying tips When the frying is finished Induction hob Cooking zonesOperating power settings Heating acceleratorCookware Cooking hob lock-out Cookware detector signalResidual heat Circuit board thermal protectionTemperature Glass ceramic hob thermal protectionWarming function Cleaning the gas components Cleaning and MaintenanceCleaning stainless steel Ordinary daily cleaningCleaning the glass ceramic hob Cleaning the barbeque plateCleaning the deep fat fryer Positioning in the counter top Instructions for the installerInstalling the Appliance Fixing to the supporting structureFixing to the electric model support structure Instructions for the installer Electrical connection Do not remove this plate for any reasonGAS Connection Connection to liquid gasRoom ventilation Extraction of the combustion productsReplacement of nozzles on the hob Adaptation to Different Types of GASBurner and nozzle characteristics table Liquid GAS G30/G31 30/37 mbarFinal Operations for GAS Appliances Adjusting the minimum for city and natural gasAdjusting the minimum for liquid gas Lubrication of gas taps