| Instructions for the installer |
| |||||
| 10.2 Burner and nozzle characteristics table |
|
| |||||
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| RATED |
|
|
|
|
|
|
Burner | HEATING |
| LIQUID GAS – G30/G31 30/37 mbar |
| ||||
CAPACITY |
|
| ||||||
|
|
|
|
|
|
|
| |
|
| (KW) |
|
|
|
|
|
|
|
|
| Nozzle | Reduced | Capacity | Capacity | ||
|
|
| diameter | capacity | ||||
|
|
| 1/100 mm | g/h G30 | g/h G31 | |||
|
|
| 1/100 mm | (W) | ||||
|
|
|
|
|
|
| ||
Auxiliary (1) | 1.05 | 50 | 28 * | 30 ** | 350 | 76 | 75 | |
1.75 | 65 | 32 * | 33 ** | 450 | 127 | 125 | ||
Rapid (3) | 2.3 | 75 | 42 * | 45 ** | 800 | 167 | 164 | |
3.5 | 94 | 63 * | 65 ** | 1500 | 254 | 250 | ||
3.9 | 100 | 63 * | 65 ** | 1500 | 284 | 278 | ||
Fish burner (6) | 1.9 | 68 | 42 * | 45 ** | 900 | 138 | 136 |
*/**: the diameters market with * and ** must be respectively fitted onto the taps marked with * and ** seen in the paragraph"11.1 Adjusting the minimum for city and natural gas".
Burner | RATED HEATING | METHANE GAS – G20 20 mbar | |||
CAPACITY | (KW) | ||||
|
|
| |||
|
|
| Nozzle diameter 1/100 | Reduced capacity (W) | |
|
|
| mm | ||
|
|
|
| ||
Auxiliary (1) | 1.05 |
| 72 | 350 | |
1.75 |
| 97 | 450 | ||
Rapid (3) | 2.5 |
| 108 | 800 | |
3.5 |
| 133 | 1500 | ||
3.9 |
| 135 | 1500 | ||
Fish burner (6) | 1.9 |
| 94 | 900 | |
Burner | RATED HEATING | CITY GAS – G110 8 mbar | |||
CAPACITY | (KW) | ||||
|
|
| |||
|
|
| Nozzle diameter 1/100 | Reduced capacity (W) | |
|
|
| mm | ||
|
|
|
| ||
Auxiliary (1) | 1.05 |
| 145 | 350 | |
1.75 |
| 185 | 450 | ||
Rapid (3) | 2.5 |
| 230 | 800 | |
3.5 |
| 290 | 1500 | ||
3.8 |
| 350 | 1500 | ||
Fish burner (6) | 1.9 |
| 190 | 900 | |
|
|
|
|
|
To identify the burners on your hob, refer to the drawings in point "4. GET TO KNOW YOUR APPLIANCE".
67