True Food Service Equipment, Inc.
MAINTENANCE, CARE & CLEANING
MAINTENANCE, CARE & CLEANING
CLEANING THE CONDENSER COIL
When using electrical appliances, basic safety precautions should be followed, including the following:
Disconnect power to unit.
Three door units will need the rainshield removed to easily access the condenser coil for cleaning. Back out the top screws (see image 2) and the bottom screws (see image 3) anchoring the rainshield. Unplug the wires connected to the rear of the digital temperature thermometer (see image 3) and set the rainshield to the side.
NOTE (For Three Door Units Only): Remember to mark which wire plugs into the rear of the digital tem- perature thermometer for easy assembly of the rain- shield.
Clean off accumulated dirt from the condenser coil and the fan with a stiff bristle brush. After brushing the components off vacuum all dirt residue from the coil, fan, and surrounding areas.
NOTE: Single door freezer models are supplied with a long handle stiff bristle brush. This brush is used to reach through tight clearances when cleaning the con- denser coil. (See Image 1)
1
Single Door Freezer unit (Brush Provided)
| 2 |
|
| 3 |
|
Three Door Freezer unit | Three Door Freezer unit | ||||
(Rainshield Removal/top | (Rainshield Removal / bottom | ||||
screws) | screws) |
4
Digital Temperature Control Connections.
(Rainshield Removal)
16 | www.truemfg.com | 16 |