DCS BGB48-BQR, BGB48-BQAR manual Side Burners BGB48 BQR Model, Smoker Burner

Page 32

CARE AND MAINTENANCE

Fig. 48

Note:

When replacing grill and/or smoker burners, or orifices following cleaning, confirm orifice penetration into burner as shown in Fig. 48

Be careful not to upset the air shutters’ original

 

 

position (unless readjusting). Lower the rear of the

 

Cap

burner into the cutouts on the support channel at the

 

rear of the burner box. Make sure it is level and does

 

 

not rock. Light all of the burners and check for proper

 

 

flame characteristics. If adjustments are necessary,

 

 

refer to page 17. Do this prior to cooking on the grill.

Brass Ring Locat-

Main

 

ing Pins

 

Burner

 

 

SIDE BURNERS (BGB48 BQR MODEL):

 

Port Ring

 

 

For proper lighting and performance keep the burners

 

 

clean. It is necessary to clean the burners if they do

 

 

not light even though the electrode clicks, if there has

 

 

been a severe boil over, or when the flame does not

Locating Notch

 

burn blue. Be certain all burner knobs are in the off

 

 

 

position before attempting to clean the burners. The

Electrode

 

burners have been designed for ease in cleaning.

 

Burner

When the grates and burners are cool, remove the

 

Base

grate. The burner cap and the brass port ring can

 

 

easily be lifted off. Wash these parts in hot soapy

 

 

water, rinse and dry thoroughly. The burner caps are

 

Venturi

porcelain enamel. Follow the directions on the

 

 

previous page for cleaning that were given for the

Locating Holes

 

burner grates. A bristle brush can be used to clean

 

 

 

out the toothed burner ports, if necessary. After

 

 

cleaning, it is important to make sure the location pins

FIG. 49

 

on the bottom side of the port ring are properly

 

 

aligned with the corresponding holes in the base.

 

 

Incorrect alignment will produce a potentially dangerous flame and poor burner performance (see Fig. 49).

SMOKER BURNER:

The smoker burner can be removed and cleaned by unplugging the electrode wire and lifting out the burner. Cleaning is similar to the grill burner. Replace the burner by sliding the air shutter over the brass orifice, centering it in the hole.

30

Image 32
Contents Professional 36/48 BGB Grill Page Message to OUR Customers Please Retain this Manual for Future ReferenceTable of Contents Safety Practices & Precautions Important Safety NoticeGrill Placement Preferred AIR FlowSafety Practices & Precautions Grill Models Location InstallationLocating GRILL/BUILT-IN Clearances Clearances to Non-Combustible Construction Clearances to Non-Combustible ConstructionInsulated Jacket Clearances to Combustible ConstructionGeneral BUILT-IN Construction Details Access Drawers Cutout dimensions GAS HOOK-UP LP Tank Requirements LP GasLP Tank Restraint for BUILT-IN Installation 18 maxStep To Test Leak TestingBefore Testing Burner Adjustment Grill Burner AIR AdjustmentLOW Flame Setting Adjustment Grill Burner Flame HeightRadiant Assembly Radiant Asssembly InstallationInstaller Checklist These InstructionsTo Light the Grill Burner Using the GrillLighting Instructions Grilling DIRECT/INDIRECT Cooking NotesBurner Burner OffShaped Grate Radius Grate Grilling HintsDUAL-SIDED Grates Wood Chips Using the Smoker SystemTo Light the Smoker Burner Using the Rotisserie ROD LightPreparation RecommendedWorking Area Meat PreparationTo Light the Rotisserie Burner Before Cooking Manual LightingCooking on Rotisserie Care and Maintenance To Remove the U-BURNERS for Cleaning Grill Burner CleaningOrifice Cleaning Stainless SteelSide Burners BGB48 BQR Model Smoker BurnerTroubleshooting Before Calling for ServiceGrill WON’T Light When the Ignition Button is Pushed LOW Heat with Knob in HI/SEAR PositionService HOW to Obtain ServiceWarranty Limited WarrantyHOW Long does this Limited Warranty LAST? This Warranty does not CoverNo Other Warranties HOW to GET ServiceCommercial USE LE Gril DE Série Professionnelle BGB 36/48 PO Lintention DE NOS Clients Veuillez Conserver CE Manuel À Titre DE RéférenceTable DES Matières Mesures DE Sécurité ET DE Précaution AutocollantDe ventilation Emplacement DU Gril Flux Dévent DE SortieRemarque Modèles DE Gril Emplacement DU Gril ET DES Dégagements EmplacementEspaces de dégagement pour une construction non combustible Généralités Enveloppe IsoléeDétails Dune Construction Intégrée Disposition standard pour une enceinte non combustible+0,-1/8 +1/8,-0 Branchement DU GAZ Exigences Concernant LE GAZBranchement DU GAZ Naturel Pour Connecter LES Raccords Fournis Avec LE GrilMise EN Garde Exigences Concernant LA Bouteille DE PropaneRemarque Placez le dispositif de retenue de bouteille dans lîlot Fig Pour tester Test DE Détection DES FuitesAvant la vérification Réglages DES Brûleurs Réglage Dair DU Brûleur DU GrilHauteur DES Flammes DU Brûleur DU Gril Réglages Pour Niveau BASInstallation DE Lensemble DU Radiant Installation DE Lensemble DU RadiantListe DE Contrôle DE Linstallateur Utilisation DU Gril Instructions DallumagePour Allumer LE Brûleur DU Gril Allumage du gril à lallumetteInstructions DALLUMAGE/CUISSON SUR Gril Allumage des brûleurs latéraux avec une allumetteBrûleurs latéraux GrilCuisson SUR Gril Conseils AU Sujet DU GrilGrilles Double Face Grille EN Forme DE « W » Grille ArondieCopeaux DE Bois Utilisation DU Système À FumoirPour Allumer LE Brûleur À Fumoir Utilisation DE LA Rôtissoire Recommandé PréparationPour Allumer LE Brûleur DE Rôtisserie Avant DE Faire Cuire Allumage ManuelCuisson SUR LA Rôtissoire Entretien ET Nettoyage Acier Inoxydable ÉlectrodesBrûleur DU Gril Déposer DES Brûleurs EN U Pour LE NettoyageBrûleurs Latéraux BGB48 BQR Modele Brûleur À FumoirAvant Dappeler LE Service Technique DépannageLE Gril NE Sallume PAS Lorsquon Enfonce LE Bouton Dallumage Chaleur Faible Avec LE Bouton EN Position « SEAR/HI »Pour Lobtention DU Service DE Garantie Garantie Garantie LimitéeFisher & Paykel Sengage À Quelle EST LA Durée DE Cette Garantie LIMITÉE?Aucune Autre Garantie Pour Obtenir DES RéparationsUtilisation Commerciale Remarque Page Litho in USA 09/2001

BGB48-BQAR, BGB48-BQR specifications

The DCS BGB48-BQR and BGB48-BQAR are cutting-edge battery systems designed for a range of applications, primarily focusing on delivering reliable energy storage solutions. These models are part of a contemporary line of products that exemplify advanced technologies in battery management and energy efficiency.

One of the key features of the BGB48-BQR and BGB48-BQAR is their high energy density, which maximizes the usable energy within a compact form factor. This is particularly beneficial for applications that require a substantial amount of energy but have limited space for battery installation. The sleek design not only enhances the aesthetics of installations but also allows for flexible integration into existing systems.

The technology utilized in these batteries includes lithium-ion cells, which are renowned for their longevity and performance. With a cycle life that often surpasses 3,000 cycles, users can expect these batteries to maintain their capacity over extended periods, reducing the need for frequent replacements. This durability translates into lower operational costs and less environmental impact.

Another standout characteristic is the sophisticated Battery Management System (BMS) integrated into both models. The BMS continuously monitors the health of each battery cell, ensuring optimal performance and safety. It balances charging and discharging processes, mitigates risks of overcharging or overheating, and extends the overall lifespan of the battery. Additionally, the BMS provides real-time data to users, facilitating informed decision-making regarding energy consumption and battery usage.

Safety is a paramount consideration in the design of the DCS BGB48-BQR and BGB48-BQAR systems. These batteries incorporate multiple layers of protection, including thermal management that prevents overheating, as well as protective circuits that safeguard against short circuits and electrical surges.

Furthermore, both models support various communication protocols, enabling seamless integration with smart energy systems. This feature allows them to interact with solar panels, inverters, and grid systems, making them suitable for renewable energy applications and storage.

In summary, the DCS BGB48-BQR and BGB48-BQAR represent the forefront of battery technology with their high energy density, advanced BMS, robust safety features, and adaptability for a diverse range of applications. These characteristics make them an ideal choice for businesses and individuals seeking efficient, reliable, and sustainable energy storage solutions.