Blodgett KLS-40G, KLS-60G, KLS-20G manual Service Connections, Utility Information

Page 4

1.0SERVICE CONNECTIONS

UTILITY INFORMATION:

GAS:

ELECTRIC:

KLS-20G-Total 100,000 BTU. One 1" male connection

STANDARD: 115/60/1 - furnished with 6 ft. cord w/3-prong

(for location, see drawing below.) Natural Propane

plug. Total maximum amps 2.0.

Required operating pressure: Natural Gas 4" W.C.; Propane

OPTIONAL: 208/60/1 or for use on 3 (190 to 219 volts) -

Gas 10" W.C

 

supply must be wired to unit - see drawing below. Total

KLS-40G- Total 100,000 BTU. One 1" male connection.

maximum amps 1.0.

(for location, see drawing below.) Natural Propane

OPTIONAL: 240/60/1 or for use on 3 (220 to 240 volts) -

Required operating pressure: Natural Gas 4" W.C.; Propane

Gas 10" W.C

supply must be wired to unit - see drawing below. Total

GL-60E- Total 130,000 BTU. One 1" male connection

maximum amps 1.0.

 

(for location, see drawing below.) Natura Propane.

 

Required operating pressure: Natural Gas 4" W.C.; Propane

 

Gas 10" W.C.

 

 

 

 

 

 

DIMENSIONS

 

 

 

 

 

 

 

MODEL

CAPACITY

UNITS

A

B

C

D

E

F

G

H

J

K

L

KLS-20G

20 gallons

inches

20

31.25

40

32

3

19

64

24

30.5

6.0

18.25

76 litres

mm

508

794

1016

813

76

483

1626

610

775

152

464

 

KLS-40G

40 gallons

inches

26

35.5

44

38.5

2

19

72

29

35

6.0

22

152 litres

mm

660

902

1118

978

51

483

1829

737

889

152

559

 

KLS-60G

60 gallons

inches

30

40

49.5

42

2.5

21.5

85

35

39

8.0

24.62

227 litres

mm

762

1016

1257

1016

63

546

2159

889

991

203

625

 

 

 

 

 

 

 

 

 

KLS-20G = Ø 20.75"

 

 

 

 

 

 

 

 

 

GC

 

 

KLS-40G = Ø 26.75"

 

 

 

 

 

 

 

 

 

 

 

 

KLS-60G = Ø 30.75"

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

120° X 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

FRONT

 

 

 

 

 

 

EC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6(152)

 

 

 

 

DIMENSIONS ARE IN INCHES [MM]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLOSED 5.5(140)

STANDARD

 

 

 

 

 

 

 

 

 

 

OPENED 7.5[191]

E

 

 

 

 

 

 

 

 

 

Ø 2(51] VALVE

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

ØA

 

 

 

 

 

 

 

L

 

 

 

G

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

J

 

 

EC

 

 

 

 

 

 

GC

 

 

 

 

 

 

 

 

F

 

EC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

 

GC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

Image 4
Contents KLS-20G, KLS-40G and KLS-60G Important Notes for Installation and Operation Table of Contents Description Service Connections Utility InformationInstallation Installation Codes and Standards Sides Inches Back Inches AT Flue BOX FloorsTo Install InstallationGAS Connection Water Connection Installation Installation Performance Check GAS Control Instructions OperationStartup Complete Shutdown StandbyRelighting Spark Igniter Failure Wait a Minimum of 5 Minutes Before ProceedingFront Panel Controls Daily Operation END User TipsEND User Tips GAS Saving TipsDaily MaintenanceMonthly Cleaning Instructions DRAW-OFF Valve Cleaning Cleaning InstructionsDairy DRAW-OFF Valve Cleaning What to do if Surface Rust Appears Stainless SteelCleaning Instructions Stainless Steel Service General Orifice SizeUnit Total Input Natural Manifold PressureNatural Propane Pilot Orifice SizesGAS Pressure Regulator Pressure Switch AdjustmentsThermostat Pressure Switch To Adjust Pressure SwitchRE-ESTABLISHING Vacuum Adding WaterControl Circuit Fuses Converting Between Natural and Propane GAS Converting Between Natural and Propane GAS Troubleshooting Problem Look for Troubleshooting Problem Look for Product DOW Chemical Canada INCCOMPOSITION/INFORMATION on Ingredients CAS#Hazards Identification Emergency Overview Fire Fighting Measures Flammable Properties First AIDFlammability Limits Handling and Storage Physical and Chemical Properties Exposure CONTROLS/PERSONAL ProtectionStability and Reactivity Mutagenicity Environmental FateTransport Information Regulations Toxic Substances Control ACT TscaChemical Name CAS Number List PA1Canadian Environmental Protection ACT Cepa Canadian RegulationsOther Information

KLS-40G, KLS-60G, KLS-20G specifications

Blodgett KLS series ovens, specifically the KLS-20G, KLS-40G, and KLS-60G, represent the pinnacle of cooking technology designed for both commercial kitchens and culinary professionals. These ovens are engineered to meet diverse cooking needs while delivering exceptional performance, making them invaluable assets in any bustling food service environment.

The KLS-20G, KLS-40G, and KLS-60G models differ primarily in their cooking capacities, with each model tailored for a specific scale of operations. The KLS-20G, with its compact design, is perfect for smaller establishments or those requiring flexibility in their kitchen space. The KLS-40G and KLS-60G, on the other hand, are suited for larger operations that demand increased production capabilities.

One of the standout features of the KLS series is its innovative cooking technology. Each oven is equipped with advanced digital controls that allow for precise temperature management and programmable cooking settings. This ensures consistent results every time, maximizing food quality and minimizing waste. The ovens also incorporate a highly efficient convection cooking system, which circulates hot air evenly throughout the cooking chamber, promoting faster and more uniform cooking.

Additionally, Blodgett’s self-cleaning technology sets these models apart from competitors. This feature significantly reduces labor costs and time spent on maintenance, allowing kitchen staff to focus on food preparation rather than cleaning. Furthermore, the ovens are designed with durability in mind, utilizing high-quality stainless steel that withstands the rigors of a busy kitchen environment.

Energy efficiency is another core characteristic of the KLS series. With features like insulated doors and optimized heating elements, these ovens reduce energy consumption while maintaining high performance levels. This not only lowers operational costs but also contributes to a more sustainable kitchen.

In terms of versatility, Blodgett KLS ovens are equipped with multiple cooking modes such as steam, convection, and a combination of both. This allows chefs to experiment with various culinary techniques across a wide range of dishes, from baking to roasting, broiling, and steaming.

In summary, the Blodgett KLS-20G, KLS-40G, and KLS-60G ovens are engineered to enhance performance and efficiency in professional kitchens. With features like advanced digital controls, superior cooking technology, self-cleaning capabilities, and energy efficiency, these ovens are designed to meet the demands of modern culinary operations, enabling chefs to create exceptional dishes with ease and precision.