Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers
Measuring Thermopile
Taking a Millivolt Reading
1. Make sure the multimeter is set to mV.
2.Touch the thermopile leads with the multimeter probes as shown.
Adjusting the Thermopile
1.Compare the multimeter reading to the Thermopile mV table.
Thermopile mV Table
Pilot lit | Pilot lit with burners on |
PP1 to PP2 | PP2 to TH2 approximately |
600± mV | 300 mV less than pilot alone |
2.Insert a flathead screwdriver into the Pilot Adj. cap and turn
mV Gas Valve Resistance Readings Table
Pilot Valve | Main Valve |
TH 1 to PP 2 10.4 Ω | TH 2 to PP 2 2.0 Ω |
3.Insert flathead screwdriver into Pilot Adj. screw and turn
4. Disconnect the multimeter.