Pitco Frialator L22-345 manual Replacing the Pump Relay

Page 76
Replacing the Pump Relay

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers

Replacing the Pump Relay

1.Remove the two (2) screws, which hold the pump relay, using a Phillips screwdriver.

2.Remove all wires on the pump relay using needle-nose pliers. See “Simplified Wiring Diagrams on page 89.

3.Remove the pump relay.

4.Reinstall the new pump relay by following steps 1 through 2 in reverse.

SG/SSH Series Service Manual

76

Image 76
Contents High Efficiency Gas Fryers SG/SSH Series Solstice Service ManualL22-345R0 Notice MAILING ADDRESSSHIPPING ADDRESS EQUIPMENT REFERENECE INFORMATION24V Model Table of ContentsTheory of Operation mV Model Troubleshooting and Problem IsolationFilter System Wiring Diagrams Simplified Wiring DiagramsTheory of Operation Fryer Components Operation Heating SystemFilter System Safety SystemOptional Basket Lift Controller Operational Modes Serial Numbers 24V Model Accessing Fryer for Servicing 4. Unplug all power cords1. Press off button on control panel 2. Slide button to solid stateCleaning the Gas Valve Vent Tube Checking the Burner Manifold Gas Pressure Taking a Supply Gas Pressure ReadingSupply Pressure Table Removing Solid State Thermostat If Necessary Taking a Manifold Gas Pressure Reading Adjusting Pilot Pressure Adjusting Manifold Gas PressureManifold Gas Pressure Table Calibrating Solid State Thermostat 2.With a 5/16 inch socket, loosen the collet3.Rotate the knob to point at actual temperature 4.Tighten collet and replace knob capReplacing the Controllers and Wiring Harness Removing the Controller Front Panel BezelRemoving the Solid State Wiring Harness 6. Remove the controller wiring harness Replacing the Relay Board and Paper Replacing the Ignition Module Replacing the Spinal Tap 8. Disconnect the connection from the valve Side View of Plugs Top View of PlugsReplacing an Igniter/Pilot Assembly 10. Remove the burner Replacing the Self‐Cleaning Burner Solenoid Replacing the Gas Valve SG/SSH Series Service Manual Replacing the Transformer Box 9.Remove the transformer Replacing the DVI Switch Replacing the Burner Assembly Replacing the Burners11. Remove the SCB runner tube Replacing the Burner Assembly SG/SSH Series Service Manual Replacing the Frypot NOTE: For SSH models only7. Remove the flange elbow 14. Remove the splash back by lifting up NOTE: Lifting the tank requires two 2 technicians Removing the Basket Lift Cover Replacing the Basket Lift ComponentsReplacing the Transformer Replacing the Basket Lift Driver Board Adjusting the Magnetic Sensor Replacing the Basket Lift Actuator5.Remove the top retaining bushing by unscrewing 8. Rotate up the actuator collar 9. Remove the actuator collarGas Conversion mV Model Taking an Incoming Supply Gas Pressure Reading Supply Pressure Table Taking a Manifold Gas Pressure Reading7 to 4. When adjustment is complete Adjusting the Thermopile Measuring ThermopileTaking a Millivolt Reading Thermopile mV TableReplacing the Thermostat Hi-Limit Thermostat10. Remove and replace the temperature bulb 9. Apply Teflon paste to the fitting11. Finger tighten the fitting Calibrating the Thermostat NOTESReplacing the Hi‐Limit Thermostat Filter System Replacing the Return Valve Replacing the Flush Hose Assembly and Valve 11. Remove the nut using a 7/16 inch wrench 8. Slide the bracket to the back of the assembly9. Lift bracket out and slide forward 14. Remove the piping using a 15/16 inch wrench on the valve and an adjustable wrench on the12. Remove the handle pipingReplacing the Heat Tape 1. Disconnect plug from pump boxReplacing the Waste Oil and Components Removing Rear Mounting BracketRemoving the Check Valve 4. Remove the valve lever 7.Remove the valve using two adjustable wrenches6. Lift off the mounting bracket Replacing the Filter Pump and Motor Removing the Filter Pump and Motor8. Remove the bracket Replacing Seal Kit Removing the Filter Pump from the Motor Replacing the Return Switch 11. Pull the red return handle out of the fryer Replacing the Drain Line or Gasket 3. Slide off the drain manifold gasket2. Lift off the drain manifold clamp 4.Slide out the drain lineReplacing the Pump Relay and Circuit Breaker Replacing the Circuit BreakerReplacing the Pump Relay Troubleshooting and Problem Isolation Troubleshooting and Problem Isolation Interpretation of Solid State Controller LightsSolid State Thermostat Field Calibration Component Troubleshooting Roll Out SwitchProbe Gas ValveTransformer Drain Valve and Return Valve SwitchesIgnition Module Relay Board Computer ControlDigital Solid State Control Primary Solid State ControlBackup Solid State Control Probe Resistance Chart Orifice Size Chart ModelGas Type Main BurnerOrifice Size at Sea Level Chart Orifice Size Required at Other ElevationsWiring Diagrams Simplified Wiring Diagrams Wiring Diagram – Full Vat with SCBWiring Diagram - Twin Vat with SCB Wiring Diagram – Basket Lifts Wiring Diagram – Filter Motor 115V‐60Hz Wiring Diagrams – Filter Motor 208‐240V Notes SG/SSH Series Service Manual L22-345R0