Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers
Controller Operational Modes
|
|
|
|
|
|
| TEMPERATURE |
|
MODE | ENTRY |
| INDICATION |
| SET POINT | EXIT | ||
BOIL | With control initially off, toggle |
| Power and HD |
|
| Fixed at 200°F | Press OFF to | |
OUT | the ON/OFF switch: |
| indicators are on. HFB |
| (93°C) | exit. | ||
| ON – OFF – |
| indicator flashes at 0.5 |
|
|
| ||
|
| seconds rate until exit. |
|
|
| |||
| ON – OFF – Then ON |
|
|
|
| |||
|
|
|
|
|
|
|
| |
| This sequence must be |
|
|
|
|
|
|
|
| performed within 3 seconds. |
|
|
|
|
|
|
|
MELT | Select MELT and then press |
| Same as below except |
| No set point. HD is | Automatic | ||
| ON. |
| fixed heat cycle. |
| suppressed if Vat is | switch to | ||
| Melt may be bypassed by |
|
|
|
|
| greater than 250°F | COOK after |
|
|
|
|
|
| (121°C). | temperature is | |
| pressing COOK. |
|
| ON | OFF |
| ||
|
|
|
|
| greater than | |||
|
|
|
|
|
|
|
| |
|
|
| GAS | 8 sec | 22 sec |
|
| 140°F (60°C) |
|
|
| ELEC | 4 sec | 26 sec |
|
| or press OFF |
|
|
|
|
| to exit. | |||
|
|
|
|
|
|
|
| |
COOK | Press COOK and then press |
| Power indicator is on. |
| Knob setting | Press OFF to | ||
| ON. |
| HD as required to |
|
| exit. | ||
| Automatic entry after |
| maintain Vat |
|
|
|
| |
|
| temperature. HFB |
|
|
| |||
| completed MELT cycle. |
|
|
|
| |||
|
| indicator follows HD. |
|
|
| |||
|
|
|
|
|
|
SG/SSH Series Service Manual | 9 |