Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers
Adjusting Manifold Gas Pressure
1.Check the manifold gas pressure with the manometer and compare the reading to the Manifold Gas Pressure table.
3.Insert flathead screwdriver into cap and turn
Manifold Gas Pressure Table
NAT | LP |
|
|
4.0” | 10” |
|
|
2.Insert a flathead screwdriver into the cap and turn
4. When adjustment is complete:
a. Shut off the gas supply line. b. Disconnect manometer.
c. Remove the test fitting.
d. Reinstall the gas manifold plug. e. Turn on gas supply line.
SG/SSH Series Service Manual | 53 |