Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers
Probe Resistance Chart
Probe Resistance in 5°F Increments.
Probe | Probe | Resistance |
|
Temp | Temp |
| |
(Ohms) |
| ||
(°F) | (°C) |
| |
|
| ||
10 | 562734 |
| |
15 | 483875 |
| |
20 | 417167 |
| |
25 | 360589 |
| |
30 | 312474 |
| |
35 | 1.7 | 271446 |
|
40 | 4.4 | 236370 |
|
45 | 7.2 | 206311 |
|
50 | 10.0 | 180491 |
|
55 | 12.8 | 158252 |
|
60 | 15.6 | 139055 |
|
65 | 18.3 | 122489 |
|
70 | 21.1 | 108051 |
|
75 | 23.9 | 95539 |
|
80 | 26.7 | 84644 |
|
85 | 29.4 | 75136 |
|
90 | 32.2 | 66823 |
|
95 | 35.0 | 59540 |
|
100 | 37.8 | 53146 |
|
105 | 40.6 | 47523 |
|
110 | 43.3 | 42569 |
|
115 | 46.1 | 38195 |
|
120 | 48.9 | 34328 |
|
125 | 51.7 | 30902 |
|
130 | 54.4 | 27862 |
|
135 | 57.2 | 25161 |
|
140 | 60.0 | 22755 |
|
145 | 62.8 | 20610 |
|
150 | 65.6 | 18695 |
|
155 | 68.3 | 16981 |
|
160 | 71.1 | 15446 |
|
165 | 73.9 | 14069 |
|
170 | 76.7 | 12823 |
|
Probe | Probe | Resistance | |
Temp | Temp | ||
(Ohms) | |||
(°F) | (°C) | ||
| |||
175 | 79.4 | 11719 | |
180 | 82.2 | 10716 | |
185 | 85.0 | 9812 | |
190 | 87.8 | 8995 | |
195 | 90.6 | 8255 | |
200 | 93.3 | 7586 | |
205 | 96.1 | 6979 | |
210 | 98.9 | 6427 | |
215 | 101.7 | 5926 | |
220 | 104.4 | 5470 | |
225 | 107.2 | 5055 | |
230 | 110.0 | 4675 | |
235 | 112.8 | 4329 | |
240 | 115.6 | 4013 | |
245 | 118.3 | 3723 | |
250 | 121.1 | 3458 | |
255 | 123.9 | 3214 | |
260 | 126.7 | 2991 | |
265 | 129.4 | 2785 | |
270 | 132.2 | 2597 | |
275 | 135.0 | 2422 | |
280 | 137.8 | 2262 | |
285 | 140.6 | 2113.9 | |
290 | 143.3 | 1977.3 | |
295 | 146.1 | 1851.0 | |
300 | 148.9 | 1734.3 | |
305 | 151.7 | 1626.1 | |
310 | 154.4 | 1525.9 | |
315 | 157.2 | 1433.0 | |
320 | 160.0 | 1346.7 | |
325 | 162.8 | 1266.6 | |
330 | 165.6 | 1192.1 | |
335 | 168.3 | 1122.8 |
| Probe | Probe | Resistance |
| Temp | Temp | |
| (Ohms) | ||
| (°F) | (°C) | |
|
| ||
| 340 | 171.1 | 1058.23 |
| 345 | 173.9 | 998.09 |
| 350 | 176.7 | 942.00 |
| 355 | 179.4 | 889.67 |
| 360 | 182.2 | 840.78 |
| 365 | 185.0 | 795.10 |
| 370 | 187.8 | 752.38 |
| 375 | 190.6 | 712.41 |
| 380 | 193.3 | 674.95 |
| 385 | 196.1 | 639.87 |
| 390 | 198.9 | 606.96 |
| 395 | 201.7 | 576.09 |
| 400 | 204.4 | 547.09 |
| 405 | 207.2 | 519.86 |
| 410 | 210.0 | 494.24 |
| 415 | 212.8 | 470.16 |
| 420 | 215.6 | 447.49 |
| 425 | 218.3 | 426.13 |
| 430 | 221.1 | 406.02 |
| 435 | 223.9 | 387.04 |
| 440 | 226.7 | 369.14 |
| 445 | 229.4 | 352.24 |
| 450 | 232.2 | 336.29 |
| 455 | 235.0 | 321.21 |
| 460 | 237.8 | 306.94 |
| 465 | 240.6 | 293.46 |
| 470 | 243.3 | 280.69 |
| 475 | 246.1 | 268.61 |
| 480 | 248.9 | 257.15 |
| 485 | 251.7 | 246.30 |
| 490 | 254.4 | 236.00 |
| 495 | 257.2 | 226.24 |
| 500 | 260.0 | 216.96 |
NOTE: Resistance, of either probe lead, to the frame of the appliance should read as “open’ on the meter. Typically this is 1Meg ohms or more.
°C = 5/9
SG/SSH Series Service Manual | 85 |