PRODUCT DESCRIPTION

The AmericaSeries S1C/H and S2C condensing units are, air-cooled, vertically arranged side discharge, high efficiency units designed specifically to meet or ex- ceed a 13 SEER rating.

The S1C 9,000-36,000 Btuh and S1H 9,000-24,000 Btuh capacity condensing unit will provide cooling for a single evaporator, as identified in the "S1C Specifications and Dimensions" section on pages 23-24.

The S2C 18,000 (99) - 21,000 (92) and 23,000 (22) Btuh capacity condensing units will provide cooling for two evaporators, as identified on page 25 in the "S2C Specifica- tions and Dimensions" section. The S1C/H and S2C are quiet units that can be recom- mended for both commercial and residential applications.

Installation of the S1C/H and S2C condensing units is simplified by a 24v control interconnection from the evaporator and multiple units can be lined up in close proximity to an exterior wall. Service valves are recessed to reduce tampering and all 9,000-12,000 Btuh units are equipped with a Duratec Performance Package that includes an oversized suction accumula- tor with surge baffles and enhanced oil management, a factory installed solid core filter drier and loss of charge switch. A field installed crankcase heater is standard on S1H 09 &12 (Thermostatically controlled) models, and is available as optional equip-

ment on other models.

INSTALLER SUPPLIED ITEMS

Power wiring

Low volt wiring (18 awg minimum)

Secure mounting pad or foundation

Refrigerant piping (if not purchased from EMI)

High Volt Disconnect

Refrigerant for charging interconnect piping (see charge table on page 10)

ITEMS FOR CONSIDERATION

CONTROLS and COMPONENTS

(Factory installed or supplied)

Compressor and fan motor contactor

Run capacitor

Loss of charge switch (09 - 12 only)

Low voltage terminal connections

Large capacity suction accumulator (09 - 12 only)

Solid core filter drier (09 - 12 only)

Thermostatically controlled crankcase heater (09 - 12 S1H’s)

H.P.S. (High pressure switch)

-Standard on S1H’s (heat pumps)

-Standard on S1C’s 18K and above.

Low Ambient controls for operation down to 32º F standard, factory in- stalled on all S1H’s (heat pumps)

Thermostatically controlled crankcase heater – This feature energizes the crank- case heater only when needed, removes the heater from the electrical circuit at conditions where it’s not required, saving unnecessary Watts, and increasing overall system efficiency.

System OPTIOns

Field installed crankcase heater for straight cool units (standard on 9,000-12,000 Btuh S1H’s Thermostati- cally controlled)

Straight cool hard start (standard on all S1H’s)

115v (9,000-12,000 btuh only)

copper/copper coils (sea coast use)

Low Ambient controls for operation down to 32º F, specify this option for S1C or S2C systems (standard on S1H’s) that will be operated in cooling mode at outside temperatures below 60º F (field installed kit)

Low Ambient for operation down to 0º F for S1C, S1H or S2C systems (consult factory for availability)

Low Ambient controls are required when the system is asked to cool at outdoor tem- peratures below 60º F, this may cause dam- age to the compressor and coil, and may

Side Discharge Condensers

3

www.enviromaster.com

Image 3
Contents Installation, operation and maintenance Manual S1C/S1H Single-Zone & S2C Dual-Zone Condensing Units Installation, operation and maintenance ManualSystem OPTIOns Controls and ComponentsItems for Consideration Installation InstructionsS1C Completed Electrical Connections High Volt ConnectionRefrigerant Piping Installation Instructions Trap Installation Clean the ends of tubing and insert into fittings Refrigerant Processing S2C Refrigerant Charge Table Installation Instructions Refrigerant ProcessingSingle Zone Operation Charts Single Zone Operation Charts Single Zone Operation Charts Single Zone Operation Charts Single Zone Heat Pump Operation Charts Single Zone Heat Pump Operation Charts Dual Zone Operation Charts Single-Zone and Dual-Zone Condenser Sequence of Operation Preperation for Start-UpSingle-Zone and Dual-Zone Sequence of Operation Factory settings 9-24k Btu = 90 minutesWDefrost Control Board S2c specifications and dimensions S1C/S1H Specifications and dimensionsS1C Electrical Specifications S1H Electrical Specifications S2c Test Unit Performance Data Test Unit Performance Data sheetEMI’s Product Line Phone Success Drive Fax Rome, NY