CAST IRON STOVE AND
Checking Gas Connections (Cont.)
Installing Optional Wall Mount Switch - GWMS2
Installing Optional Wall Mounted Thermostat - GWMT1
15
CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION
Continued
Pressure Testing Burner System Gas
Connections
1.Open equipment shutoff valve (see Figure 30, page 14).
2.Open propane/LP supply tank valve for propane/LP burner system or main gas valve located on or near gas meter for natural gas burner system.
3.Make sure control knob of burner system is in the OFF position.
4.Check all joints from equipment shutoff valve to thermostat gas valve (see Figure 31 for propane/LP or Figure 32 for natural, page 15). Apply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.
5.Light burner system (see Lighting Instructions, page 19). Check all other internal joints for leaks.
6.Turn off burner system (see To Turn Off Gas to Appliance, page 19).
Equipment | Propane/LP |
Shutoff | |
Valve | Supply Tank |
Gas Valve |
|
Figure 30 - Checking Gas Joints for Propane/LP Gas Burner System (Oxford™ Model Shown)
INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2
1.Connect one terminal of 25 ft. wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 33. If wires are not connected as shown, the switch will not work.
2.Route the 25 ft. wire through openings provided on the sides of the burner system to a convenient location to mount your switch.
3.Connect one bare wire end to each of the terminals of the GWMS2 wall switch.
4.Install the wall switch and cover in the wall.
To Control Switch or
Optional Accessory
Figure 33 - Control Valve Terminals
INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1
WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures.
WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard
Gas Valve |
Equipment Shutoff Valve
Gas Meter
will occur.
1.Open lower door panel. The valve is attached to the underside of the burner system assembly.
2.Disconnect from the valve the wires running from the ON/ OFF switch.
3.Connect one terminal of the wire for the wall thermostat to the THTP terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 33. If wires are not connected as shown the thermostat will not work.
Figure 32 - Checking Gas Joints for Natural Gas Burner System (Oxford™ Model Shown)