SPECIFICATIONS

SPECIFICATIONS

 

SBVBN(D)

SBVBP(D)

 

30,000 Btu/h

28,000 Btu/h

 

 

 

Gas Type

Natural

Propane/LP

 

 

 

Ignition

Piezo

Piezo

 

 

 

Manifold Pressure

3.5" w.c.

10.0" w.c.

Minimum Inlet Supply Pressure

5.0" w.c.

11.0" w.c.

Thermal Efficiency

70%

70%

 

 

 

Dimension, Inches/mm (HxWxD)

 

 

Stove and Burner System

27" x 21 1/2" x 18"

27" x 21 1/2" x 18"

 

68.6 x 54.6 x 45.7 cm

68.6 x 54.6 x 45.7 cm

Carton (Insert Only)

23 3/4" x 33 1/2" x 23 1/2"

23 3/4" x 33 1/2" x 23 1/2"

 

60.3 x 85.1 x 59.7 cm

60.3 x 85.1 x 59.7 cm

 

 

 

Weight, lbs/kg

 

 

Burner System

70 lbs/31.8 kg

70 lbs/31.8 kg

Shipping

75 lbs/34 kg

75 lbs/34 kg

27

For morevisit www..com

112127-01B

Image 27
Contents Series Stove For Your SafetyFor Your Safety What to do if YOU Smell GAS VH series StoveSafety Information Table of ContentsProduct Identification Product Features PRE-INSTALLATION PreparationLocal Codes Stove Body Assembly Cast Iron Stove and B-VENT Burner System AssemblyOxford or Victor Hearth Models Removing Front Surround PanelRemoving Screen Optional Amity ModelsInstalling Optional Blower Accessory Installing B-VENT Burner System Into Stove BodySecurely in place before venting pipes are installed Installing Rear CoverInstallation Precautions Venting InstallationVertical Checking Vent CapacityHigh Altitude Installation ChimneysRelining Systems Causes of Spillage and Corrective Action Troubleshooting Venting ProblemsCast Iron Stove and B-VENT Burner System Installation Flue GAS SpillageInstallation Items Needed Installing GAS Piping to Stove LocationTest Pressures In Excess Of 1/2 Psig 3.5 kPa Connecting STOVE/BURNER System to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsWill occur Installing Optional Wall Mount Switch GWMS2Installing Optional Wall Mounted Thermostat GWMT1 Pressure Testing Burner System Gas ConnectionsInstalling Battery in Receiver Installing Remote ReceiverREMOVING/REPLACING Glass Door Installing 9-Volt Battery in Hand-Held Remote Control UnitRemove glass door. See Removing/Replacing Glass Door, Installing LOGS, Lava ROCK, and Glowing EmbersTo Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Stove with B-VENT Burner System Lighting InstructionsOperating Stove with Vent Burner System Optional Remote Thermostat Series OperationON/OFF Series Models Ghrcb and Cghrcb Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementService Hints Replacement PartsTechnical Service Wiring DiagramSbvbnd Sbvbpd SpecificationsModels Sbvbnd and Sbvbpd Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListIndicates Color Suffix Designation Oxford Amity Stove BodyVictor Hearth Stove Body Description QTY Indicates Color Suffix DesignationStove Hearth Base GC10SPA AccessoriesReceiver and HAND-HELD Remote Control KIT Ghrcb and Cghrcb THERMOSTATICALLY- Controlled Blower KIT CDA3620TBOwners Registration Form Postage Required 112127-01B Warranty Information