Desa SBVBP installation manual Table of Contents, Safety Information

Page 2

2

TABLE OF CONTENTS SAFETY INFORMATION

TABLE OF CONTENTS

 

SAFETY INFORMATION

2

PRODUCT IDENTIFICATION

3

LOCAL CODES

4

PRODUCT FEATURES

4

PRE-INSTALLATION PREPARATION

4

CAST IRON STOVE AND B-VENT BURNER

 

SYSTEM ASSEMBLY

5

VENTING INSTALLATION

9

TROUBLESHOOTING VENTING PROBLEMS

12

CAST IRON STOVE AND B-VENT BURNER

 

SYSTEM INSTALLATION

12

OPERATING STOVE WITH B-VENT BURNER SYSTEM

19

INSPECTING BURNERS

21

CLEANING AND MAINTENANCE

22

TROUBLESHOOTING

23

REPLACEMENT PARTS

26

TECHNICAL SERVICE

26

WIRING DIAGRAM

26

SERVICE HINTS

26

SPECIFICATIONS

27

ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST

28

ACCESSORIES

32

OWNER’S REGISTRATION FORM

33

WARRANTY INFORMATION

Back Cover

SAFETY INFORMATION

WARNINGS

WARNING:Thisproductcontainsand/orgenerates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this stove and burner system. Improper use of this stove and burner system can cause serious injury or death from burns, fire, explosions, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

This stove with burner system is a vented product. This stove with burner system will not produce any gas leakage into your home if properly installed. This unit must be properly installed by a qualified service person. The glass door must be properly seated and sealed. If thisunit isnotproperly installedbyaqualified servicepersonwith glass door properly seated and sealed, gas leakage can occur.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the burner system may not have been installed properly. Get fresh air at once! Have stove with burner system inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include preg- nant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural and Propane/LP Gas: Natural and propane/LP gases are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this stove with B-vent burner system.

WARNING: Any change to this stove or burner system or its controls can be dangerous.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.

2.For propane/LP burner system, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use pro- pane/LP fuel tank of less than 100 lbs. capacity.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach you gas supplier, call the fire department.

4.Never install the stove

in a recreational vehicle

where curtains, furniture, clothing, or other flammable ob- jects are less than 42" from the front, top, or sides of the stove with burner system

in high traffic areas

in windy or drafty areas

For..com

112127-01B

Image 2
Contents VH series Stove For Your SafetyFor Your Safety What to do if YOU Smell GAS Series StoveTable of Contents Safety InformationProduct Identification Local Codes Product FeaturesPRE-INSTALLATION Preparation Cast Iron Stove and B-VENT Burner System Assembly Stove Body AssemblyAmity Models Removing Front Surround PanelRemoving Screen Optional Oxford or Victor Hearth ModelsInstalling B-VENT Burner System Into Stove Body Installing Optional Blower AccessoryInstalling Rear Cover Securely in place before venting pipes are installedVenting Installation Installation PrecautionsChecking Vent Capacity VerticalRelining Systems High Altitude InstallationChimneys Flue GAS Spillage Troubleshooting Venting ProblemsCast Iron Stove and B-VENT Burner System Installation Causes of Spillage and Corrective ActionInstalling GAS Piping to Stove Location Installation Items NeededChecking GAS Connections Connecting STOVE/BURNER System to GAS SupplyPressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 Psig 3.5 kPaPressure Testing Burner System Gas Connections Installing Optional Wall Mount Switch GWMS2Installing Optional Wall Mounted Thermostat GWMT1 Will occurInstalling Remote Receiver Installing Battery in ReceiverInstalling 9-Volt Battery in Hand-Held Remote Control Unit REMOVING/REPLACING Glass DoorInstalling LOGS, Lava ROCK, and Glowing Embers Remove glass door. See Removing/Replacing Glass Door,Lighting Instructions For Your Safety Read Before LightingOperating Stove with B-VENT Burner System To Turn OFF GAS To ApplianceON/OFF Series Models Ghrcb and Cghrcb Operating Stove with Vent Burner SystemOptional Remote Thermostat Series Operation Inspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveWiring Diagram Replacement PartsTechnical Service Service HintsSpecifications Sbvbnd SbvbpdIllustrated Parts Breakdown Models Sbvbnd and SbvbpdParts List KEY Part Number Description QTYVictor Hearth Stove Body Indicates Color Suffix Designation Oxford AmityStove Body Indicates Color Suffix Designation Description QTYTHERMOSTATICALLY- Controlled Blower KIT CDA3620TB AccessoriesReceiver and HAND-HELD Remote Control KIT Ghrcb and Cghrcb Stove Hearth Base GC10SPAOwners Registration Form Postage Required 112127-01B Warranty Information