Desa SBVBP Connecting STOVE/BURNER System to GAS Supply, Checking GAS Connections

Page 14

14

CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION

Installing Gas Piping to Stove Location (Cont.)

Connecting Stove/Burner System to Gas Supply

Checking Gas Connections

CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION

Continued

We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 28, page 13. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly.

CONNECTING STOVE/BURNER SYSTEM TO GAS SUPPLY

Installation Items Needed

5/16" hex socket wrench or nut-driver

sealant (resistant to propane/LP gas, not provided)

1.Open lower door panel.

2.Route flexible gas line (provided by installer) from equipment shutoff valve to burner system (see Figure 29). Route flexible gas supply line and attach to valve.

3.Check all gas connections for leaks. See Checking Gas Connections, column 2.

To Flare Fitting on

Control Valve

Equipment

Shutoff Valve

Flexible Gas Line from

To Gas Supply

Equipment Shutoff Valve

Provided by Installer

(Natural)

 

To External Regulator

 

(Propane/LP)

Figure 29 - Flexible Gas Line

 

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply noncorrosive leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping systems. Pressures in excess of 1/2 psig (3.5 kPa) will damage burner system gas regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas burner system or opening main gas valve located on or near gas meter for natural gas burner system, or using compressed air.

4.Check all joints of gas supply piping system. Apply noncorro- sive leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

5.Reconnect burner system and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 30).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas burner system or opening main gas valve located on or near gas meter for natural gas burner system, or using compressed air.

3.Check all joints from propane/LP supply tank or gas meter to equip- ment shutoff valve (see Figure 31 for propane/LP or Figure 32 for natural, page 15). Apply noncorrosive leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Open

Equipment

Shutoff Valve

Closed

Figure 30 - Equipment Shutoff Valve

For..com

112127-01B

Image 14
Contents VH series Stove For Your SafetyFor Your Safety What to do if YOU Smell GAS Series StoveTable of Contents Safety InformationProduct Identification Local Codes Product FeaturesPRE-INSTALLATION Preparation Cast Iron Stove and B-VENT Burner System Assembly Stove Body AssemblyAmity Models Removing Front Surround PanelRemoving Screen Optional Oxford or Victor Hearth ModelsInstalling B-VENT Burner System Into Stove Body Installing Optional Blower AccessoryInstalling Rear Cover Securely in place before venting pipes are installedVenting Installation Installation PrecautionsChecking Vent Capacity VerticalRelining Systems High Altitude InstallationChimneys Flue GAS Spillage Troubleshooting Venting ProblemsCast Iron Stove and B-VENT Burner System Installation Causes of Spillage and Corrective ActionInstalling GAS Piping to Stove Location Installation Items NeededChecking GAS Connections Connecting STOVE/BURNER System to GAS SupplyPressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 Psig 3.5 kPaPressure Testing Burner System Gas Connections Installing Optional Wall Mount Switch GWMS2Installing Optional Wall Mounted Thermostat GWMT1 Will occurInstalling Remote Receiver Installing Battery in ReceiverInstalling 9-Volt Battery in Hand-Held Remote Control Unit REMOVING/REPLACING Glass DoorInstalling LOGS, Lava ROCK, and Glowing Embers Remove glass door. See Removing/Replacing Glass Door,Lighting Instructions For Your Safety Read Before LightingOperating Stove with B-VENT Burner System To Turn OFF GAS To ApplianceON/OFF Series Models Ghrcb and Cghrcb Operating Stove with Vent Burner SystemOptional Remote Thermostat Series Operation Inspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveWiring Diagram Replacement PartsTechnical Service Service HintsSpecifications Sbvbnd SbvbpdIllustrated Parts Breakdown Models Sbvbnd and SbvbpdParts List KEY Part Number Description QTYVictor Hearth Stove Body Indicates Color Suffix Designation Oxford AmityStove Body Indicates Color Suffix Designation Description QTYTHERMOSTATICALLY- Controlled Blower KIT CDA3620TB AccessoriesReceiver and HAND-HELD Remote Control KIT Ghrcb and Cghrcb Stove Hearth Base GC10SPAOwners Registration Form Postage Required 112127-01B Warranty Information