16
CAST IRON STOVE AND
Installing Optional Wall Mounted Thermostat - GWMT1 (Cont.)
Installing Optional Wireless
CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION
Continued
4.Route the wire to a convenient location to mount your thermo- stat (no outside wall). IMPORTANT: The wire must not ex- ceed 25 feet in length.
The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace, or heat and air con- ditioning ducts.
5.Gently remove the cover of the thermostat from the base. Grasp the sides of the cover firmly and pull to separate from the base.
6.Feed the electrical wires through the rectangular slots (from the back) on each side of the base (see Figure 34).
7.Connect one bare wire end to each terminal (“W” and “R”) of the thermostat base (see Figure 35).
8.Install the base to the wall with screws provided with thermostat.
9.Move the temperature adjustment back and forth to insure the
WARNING: Do not connect this thermostat to a power source. Electrical shock and/or fire hazard will occur.
Feed wires through rectangular slots
Terminal “W”
W
INSTALLING OPTIONAL WIRELESS HAND- HELD REMOTE CONTROL ACCESSORIES - GHRCB AND GHRCTB SERIES
Installing Remote Receiver
1.Open bottom door on stove body.
2.Disconnect wires from THTP and TH on control valve that lead to the switch (see Figure 33, page 15). Discard switch plate, screws, and nuts.
3.Install battery into receiver battery clip and connect to terminals (see Figure 36).
4.Place receiver into valve bracket and align holes (see Figure 37).
5.Use
6.Connect the wires from the receiver to the valve at TH and THTP (see Figure 33, page 15).
Receiver
Terminal
Wires
| |
Battery | Battery Clip |
R
Figure 36 - Installing Battery in Receiver
Terminal “R”
Figure 34 - Back View of | Figure 35 - Thermostat |
Thermostat Base | BaseTerminal“W”and “R” |
TPTH TP TH
Figure 37 - Installing Remote Receiver
For..com