INTRODUCTION
Garland manufactures the HE Series
All units are shipped completely assembled, with top grates and radiants banded to skid in separate boxes, any loose parts are secured in place with masking tape or tie cords, and the pressure regulators (and ceramic coals, if applicable) packed inside the unit.. All units are adjusted, tested, and inspected at the factory prior to shipment..
IMPORTANT: After uncrating, immediately check the equipment for visible signs of shipping damage.. If such damage has occurred, do not refuse shipment, but contact the shipper and file the appropriate freight claims..
Rating Plate
The rating plate is attached to the front left inside broiler channel leg support..
Information on this plate includes the model and serial numbers.. When communicating with the factory about a unit or requesting special parts or information, this data is essential for proper identification.. Other information on this plate is the BTU/hr input to the burners, outlet gas pressure in inches WC, and whether orificed for natural or propane gas..
In the event you have any questions concerning the installation, use, care or service of the product, write or call our Product Service Department..
WARNING: All Garland
INSTALLATION
General Installation
IMPORTANT: Safe and satisfactory operation of your equipment depends, to a great extent, on its proper installation.. Installation must conform to local codes or, in the absence of local codes with the National Fuel Code, ANSI Z223..1 Natural Gas Installation Code, CAN/CGA
or the Propane Installation Code,
1.Installation of the equipment should be made by a licensed plumber..
2.A manual gas
3.A gas pressure regulator must be installed at the appliance prior to connecting the equipment to the gas line.. This unit is shipped with a regulator.. Failure to install a regulator will void the equipment warranty..
4.When mounting onto counter or optional HEST stand seal the broiler to the flat surface with silicone.. A NSF code requirement in many areas..
Clearances
HE Series
The appliance area must be kept free and clear of all combustibles.. Adequate clearance must be provided for air openings into the combustion chamber and for proper air supply..
These units are
1.Intended for other than household use..
2.For use in
COMBUSTIBLE | NONCOMBUSTIBLE | ||
CONSTRUCTION | CONSTRUCTION | ||
Rear | 6” (152mm) | Rear | 0” |
|
|
|
|
Sides | 6” (152mm) | Sides | 0” |
Part # 4522970 Rev 1 (10/28/09) | Page 5 |