U N P A C K I N G A N D I N S T A L L A T I O N I N S T R U C T I O N S
9 OVEN INSTALLATION
THIS OVEN CANNOT BE PROPERLY INSTALLED WITHOUT REFERRING TO THE MOUNTING INSTRUC- TIONS FOUND ON WALL AND TOP CABINET TEMPLATES.
THE NEXT STEP IS TO READ AND FOLLOW MOUNTING INFORMATION ON WALL AND TOP CABINET TEMPLATES. THIS OVEN MUST BE ATTACHED TO AT LEAST ONE WALL STUD. SEE WALL CONSTRUC-
TION ON PAGE 6.
WHEN DONE WITH TEMPLATES, PROCEED TO MOUNTING SCALE PLATE SECTION.
MOUNTING SCALE PLATE
Attach 2 Scale Plates ! with tape (not included). See Figure 16 and WALL TEMPLATE for locations.
Figure 16
Scale Plates
Mounting Plate
MOUNTING PLATE
1.Separate 4 Toggle Bolts 2, packed in the INSTALLATION HARDWARE, from the Toggle Nuts.
2.Match 5/8” holes (not in studs), drilled through WALL TEMPLATE into wall to corresponding holes on Mounting Plate.
3.Insert Toggle Bolts into matched openings on Mounting Plate. Put Toggle Nuts on Toggle Bolts. See Figure 17.
4.Position the Mounting Plate with the Toggle Bolts attached at the wall location and insert Toggle Nuts and Bolts through the holes in the wall with the Toggle Nuts closed. Figure 18. Use Wood Screws 1 to attach the Mount- ing Plate to studs.
NOTE: Before insertion, be sure you leave a space more than the thickness of the wall between the Mounting Plate and the end of each of the Toggle Nuts (in the closed position). If you do not leave enough space, the Toggle Nut will not be able to open on the other side of the wall. Also, once a Toggle Nut opens, it cannot be withdrawn from the hole; therefore make sure all of the Toggles are in the correct position before insertion.
5.Align the Mounting Plate carefully and hold in position while tightening Toggle Bolts. Pull Toggle Bolt toward you and turn clockwise to tighten. Figure 19.
Figure 17 | Figure 18 | Figure 19 |
Space more than wall thickness
Mounting
Plate
Wall
12