Protect PV.500_MH Operating Instructions
Connections:
CN1: | Internal inverter bus and power supply |
MOD1: | Ethernet connection |
CN5: | Interface for firmware update |
Configuration jumpers: | |
CN3: | All closed (default) |
LED signals:
Green LED (H1):
The green LED on the assembly indicates the global status of the assembly. The following signals are possible:
LED | Jumper | Meaning |
|
|
|
Flashing | CN3 | |
|
|
|
On | CN3 | Ready |
|
|
|
Flickering | CN3 | Ethernet CAN communication |
|
|
|
Green network LED (MOD1):
The green LED indicates communication on the network.
Yellow network LED (MOD1):
The yellow LED remains on permanently if an Ethernet network is connected.
7.2.4Installation of the COM Server
The COM server uses a communication module from Digi ("Digi Connect ME"). In order to communicate via the COM server, it must be integrated into the network and a virtual COM port must be set up on a computer. The "Digi Device Discovery" tool and a Digi RealPort driver are required for this purpose. You can find these tools at www.digi.com/support or at www.aegps.com.
Network factory settings for the COM server:
IP address: | 10.10.10.0 |
Subnet mask: | 255.255.0.0 |
Default gateway: | 0.0.0.0 |