Protect PV.500-MH Operating Instructions

Only operate the equipment in perfect working order and in ac- cordance with good electrical engineering practice

Arrange a fault detection check immediately if the equipment starts to behave differently

Keep all safety signs and warning notices on the equipment in a complete and clearly legible condition

Install fire extinguishers in the immediate vicinity of the equip- ment

1.3.2Skilled Personnel Skills and Training

Only trained and qualified skilled personnel may perform the work described, using tools, equipment and test equipment intended for the purpose and in perfect working order.

All work is coordinated and monitored by the person responsible for work. The person responsible for work is directly responsible for the execution of the work. Before work commences, the person responsible for work must inform the person responsible for the equipment and agree on a work schedule with him. The persons responsible for the work and equipment must be trained and quali- fied skilled personnel and may be one and the same person.

"Trained skilled personnel" means electricians who as a result of their specialist training:

Have knowledge and experience of the relevant standards, regulations, requirements and accident prevention regulations

Have been instructed in the mode of operation and operating conditions of the equipment

Have the ability to assess the effect of any intended work on the safe operation of this particular equipment

Can assess the work and recognise and avoid potential risks

Compliance with the safety instructions described is essential for the protection of skilled personnel and the equipment. Skilled per- sonnel must be aware of and follow these safety instructions.

8 of 68

80000043212 BAL

Image 8
Contents Protect PV.500-MH Operating InstructionsAEG Power Solutions GmbH Table of Contents Interfaces Monitoring Systems, Messages and FaultsSystem Function Graphical Display and Operation Unit Information on How to Use these Instructions WarrantyGeneral Information ValidityTarget Groups Explanations of Target GroupsObligations of the Equipment Operator HandlingSkilled Personnel Skills and Training Storing Instructions Obligations of skilled personnelSymbol Meaning Explanation of Symbols and Safety InstructionsExplanation of Symbols Safety Instructions Signal Words UsedHazard Symbols Used Symbol Meaning for skilled personnelSigns Containing Orders for Personal Protective Equipment Abbreviations Emergency Procedure e.g. in the Event of a FireSafety Awareness Lightning protection Particular Dangers associated with Photovoltaic SystemsThin-film cells Safety Signs and Warning Notices on the Equipment Safety and Protection Devices for the EquipmentSystem stop switch Protective CoversResidual Hazards Lockable Equipment DoorsGuard Electrical Hazards Risks Due to Moving Parts Fire-Related RisksWater in electrical equipment Risk of injury due to rotating fansRisks from Maintenance and Repair Work Risks due to Loss of ControlImportant information about equipment documenta- tion Product DetailsProduct Description Dimensions and Views SafetyAppropriate Use Inappropriate UseStandards, Directives and CE Mark NameplateTechnology Operating Elements System Description Individual OperationSystem Function Description of Sequence ControlOFF Status Waiting for Feed Conditions StatusOperation Status Waiting StatusFault Status Night StatusSequence Control During the Course of the Day Early morningDay EveningLater in the evening NightInverter stack switch-on time Permissible voltage dip after switching on the stackPower limit value for shutdown, delay time for shutdown Sequence Control ParametersDescription of Fan Control General Fan Control, Cabinet FanCabinet Fan Control Parameters Fan Control, Inverter Stack FanIgbt temperature limit value for switching off the fan Igbt temperature limitParameters of Inverter Stack Fan Control Insulation Monitoring and Earthing of PV Cells GeneralProtect PV.500-MH Operating Instructions Maintenance mode Operation with Thin-Film Solar CellsGeneral Sequence controlDelay for shutdown of K21 in night operation Minimum time in maintenance modeInsulation Monitoring Parameters MPP TrackerMonitoring Systems, Messages and Faults Table of Faults Temperature monitoring systemsCan I/O monitoring systems Fault/Message Unit Monitoring Systems Fault/Message DC voltage monitoring systems Fault/Message Interfaces Communication InterfaceTechnical Data MultiCom CCC hardware data assembly A29.1 Communication data port 1Communication data port 2 Communication data port 3Configuration jumpers Structure of the MultiCom CCC InterfaceConnections ButtonDescription of serial interfaces Port 2 X5 RS485 pin assignment default Shield connection of the RS485 bus lineConfiguration Port 2 X5 RS232 pin assignmentController Area Network can at Port 3 X4 can pin assignmentConfiguration Preparations Setting the terminal programProtect PV.500MH Operating Instructions Configuring the Modbus Protocol Data protocol configurationConfiguring Modbus Data Transmission Modbus/JBus data transmission configurationNetwork Connection Structure of the COM Server internally wired to A93COM Server General Installation of the COM Server Network Integration Configuration Configuration of the Virtual COM PortStructure Remote SignallingTechnical data Following default signals are used for remote signalling Graphical Display and Operation Unit DOUSignalling Acoustic signal generatorKeyboard Operation LEDsPossible symbol keys and their function Start-upMenu Structure Menu Tree Main MenuOperating Display Operating display Normal operationExamples of possible displays Example of operating displaySolar radiation is too low, the inverter is in standby mode Monthly data t = day 1 31 for the last 12 months Example of yearly overview Menu Status/Measured ValuesBlocking Menu Inverter exampleFault History SettingsService Information