Leupold PS536GS III. Quick Reference Digital Temperature Controller, SP Lock, Overtemp, Heat on

Page 18

SECTION 3 - OPERATION

III. QUICK REFERENCE: DIGITAL TEMPERATURE CONTROLLER

ENGLISH

"SP LOCK"

Light

Lights when the

set point is locked out from changes.

This setting can

only be changed by service personnel.

OVERTEMP

Light

Lights when the oven

temperature is

greater than 650°F (343°C). Refer to Quick Reference:

Troubleshooting in

this section.

Temperature

Key

Press this key once

to view the Actual

Temperature in the

Display.

Display

"HEAT ON"

Shows the Set Point

Light

or the Actual Tem-

Lights when the

perature in degrees

burner is in

Fahrenheit (F) or

operation.

Celsius (C).

 

"SET PT" (setpoint)

Light

Lights when the

set point is shown

in the display.

"ACTUAL

TEMP" Light

Lights when the Actual Tempera- ture is shown in the display.

Service Key

Service use

only.

 

 

Set Point Key

Unlock Key

 

Press this key

Press this key

Up Arrow and Down

together with the

Unlock Key to allow

together with the Set

Arrow Keys

the Set Point to be

Point Key to allow the

Set Point to be

Press these keys to

changed.

changed. Changes

adjust the Set Point up or

Changes can only be

can only be made for

down. If the Set Point will

made for 60 sec-

60 seconds.

not change, refer to Set

onds.

 

Point Key and Unlock Key

 

 

in this section.

 

18

Image 18
Contents PS536GS Gas Ovens For Your Safety EnglishTable of Contents III. Oven Specifications Oven UsesConveyor Drive Motor Moves the conveyor Electrical specifications for gas ovens per oven cavity Installation Installation KIT see Figure Recommendations II. Ventilation SystemRequirements Other ventilation concernsIII. Assembly Top Panel and Base Pad AssemblyRestraint Cable Installation StackingConveyor Installation 10 Conveyor placementFinal Assembly 12 Conveyor and master link orientationIV. Electrical Supply Additional Information Gas OvensConnection Gas Conversion During Pressure Testing Note the FollowingGAS Supply OvenEnglish Location and Description of Controls Not ShownDaily Startup Procedure Daily Shutdown ProcedureII. Normal Operation STEP-BY-STEP Overtemp III. Quick Reference Digital Temperature ControllerSP Lock Heat onMaintenance Maintenance DailySplit Belt Disassembly and Cleaning II. Maintenance MonthlyIII. Maintenance Every 3 Months Top Row T1 T2 T3 T4English IV. Maintenance Every 6 Months Blower BeltLubricating the Blower Fan Bearings KEY Spare Parts KIT QTY DescriptionEnglish II. Installation KIT QTYSingleoven Doubleoven Deutsch Français III. PANELS, END Plugs and Window IIIa. PANELS, END Plugs Without WindowEnglish IV. Control Compartment English Machinery Compartment and GAS Train Not ShownEnglish VI. Rear Compartment and Blowers Item QTY DescriptionEnglish VII. SINGLE-BELT Conveyors Item QTY Conveyor DescriptionEnglish VIII. SPLIT-BELT Conveyors English English Deutsch English English Deutsch English Español Français Deutsch Hour Service Hotline