Sonance C4630 SE Zone Line Output Connections, Line Output Fixed/Variable Switch

Page 13

C4630 SE HOME AUDIO SYSTEM

6.Press the removable connector into the corresponding zone SPEAKER OUT connector on the controller until it locks into place (see Figure 6).

The removable connectors will only fit one way on the controller.

Zone Line Output Connections

In addition to Speaker Output connectors, each zone on the C4630 SE also has a set of Line Output jacks (see Figure 6). The Zone Line Outputs let you connect high-power amplifiers to individual zones that require more power than the C4630 SE’s built-in 30 Watt/ch amplifier can provide, or expand a zone into sub-zones by using a multi- channel amplifier.

Line Output Fixed/Variable Switch

Each zone Line Output has a push-button switch that toggles the Line Output between VARIABLE (OUT) and FIXED (IN). (See Figure 6.) The VARIABLE setting allows zone keypad and remote controllers to control the level of the Line Outputs. In the FIXED setting the Line Output level cannot be varied. Keypad and remote control MUTE controls function in both the FIXED and VARIABLE settings.

Important: Do not push the Line Output FIXED /VARIABLE switch while the C4630 SE is operating. Doing so can produce high output levels that can damage the C4630 SE, the connected amplifier or the speakers.

OUTIN

VARIABLE FIXED

LL

RR

LINE OUT

34

L+L+

L-L-

R-R-

R+R+

SPEAKER OUT

8 Ω NOMINAL IMPEDANCE

Figure 6:

Zone Line Outputs, Speaker

Outputs and Line Output

Fixed/Variable Switches

NOTE: Setting a zone’s output to Fixed disables the following Sonance Control Manager Zone Setup

features for that zone: Default Volume, Maximum Volume, Page Volume, Balance, Bass, Treble. See

pages 29 and 30 .

Connecting a High-Power Amplifier in a Zone

1.Set the zone’s Variable/Fixed Output switch to the VARIABLE (OUT) position.

2.Connect a stereo RCA cable from the appropriate Zone Line Outputs on the C4630 SE to the high-power amplifier’s input connectors (see Figure 7, on page 14). The VARIABLE setting allows the zone’s volume to be controlled by the C4630 SE via a keypad or a properly-programmed IR remote.

Using a Multi-Channel Amplifier for Sub-Zone Expansion

1.Set the zone’s Variable/Fixed Output switch to the FIXED (IN) position.

2.Connect a stereo RCA cable from the appropriate Zone Line Outputs on the C4630 SE to the multi-channel amplifier’s Bus input connectors (see Figure 8, on page 14). For example, an 8-channel amplifier like the Sonamp 875D SE will let you put four speaker pairs in the zone. The FIXED output setting allows the C4630 SE’s Mute function to mute all four sub-zones. Volume for each pair of speakers in each sub-zone is controlled by an in-wall volume control.

3.Connect the Control Out on the C4630 SE to the External Control input on the sub-zone amplifier (if available) to automatically power-up the external amp when any zone on the C4630 SE is ON.

NOTE: The C4630 SE can also turn connected amplif iers ON and OFF via serial control. See page 40.

13

Image 13
Contents C4630 SE Page Ance to Rain or MOISTURE. Important Safety InformationTable of Contents C4630 SE Home Audio System Introduction C4630 SE FeaturesAudio ControlPlacement Box ContentsUnpacking Shelf-Mounting System OverviewRack-Mounting Control ConsiderationsC4630 SE Home Audio System Rear Panel C4630 SE Front Rear PanelsPower Connections Connecting the C4630 SEReplacing the AC Fuse Audio Source ConnectionsWiring the Speaker Connectors Use Good Speaker WireSource Output Connections Speaker ConnectionsConnecting a High-Power Amplifier in a Zone Line Output Fixed/Variable SwitchUsing a Multi-Channel Amplifier for Sub-Zone Expansion Zone Line Output ConnectionsC4630 SE Using a High-Power Amplifier in a ZoneIR Connections see Figure When using three or more C4630 SE Controllers, use miniPlug Y-adaptors on the IR Link jack on the Primary C4630 SE To connect to the IR Link jacks of the Secondary C4630 SEsControl Out Terminal Wiring the Control ConnectionsSync Connections Control Input/ Output Sync ConnectionsPaging Connections see Figure RS-232 Terminal Pins Connector SideRS-232 Connection see Figure RS-232C4630 SE Main Keypad see Figure C4630 SE Keypad ControllersC4630 SE Main and Numeric Keypads C4630 SE Numeric Keypad see , on Installing an IR Receiver into the KeypadKeypad Location Main Keypad IR Receiver HolsterKeypad Backlighting Jumper Connecting the IR ReceiverC4630 SE Keypad Connections To the KeypadMounting the C4630 SE Keypads External Keypad Power see FigureKeypad Ribbon Cable Insert Tool Changing the Main Keypad Source ButtonsInto Openings C4630 SE Out-Of-The-Box Functions Optional C4630 SE IR Remote ControlALL OFF Switch Front Panel Controls and IndicatorsInstalling the Sonance Control Manager Software Sonance Control Manager SoftwareTo transfer programming to the C4630 SE Transferring System Information to the C4630 SEUpdating the Sonance Control Manager Software and Firmware Upgrading Sonance Control Manager SoftwareUpgrading the C4630 SE Firmware Upgrade Firmware Warning ScreenDevice Screen Creating a New C4630 SE SystemRenaming C4630 SEs in a System with Multiple Units To cor rect for too low or too high a level Feedback , etc Setting Up a ZoneRear-Panel BBE ON/OFF Switches Setting Up SourcesBBE Sound Enhancement Device Screen Figure Programming C4630 SE Keypad MacrosGeneral Macro Programming Notes Fi g u re 4 2 Z o n e 1 P ro g r a m m i n g S c re e n Building MacrosCommand From Library IR Commands Macro Command TypesAdding an IR Command to a Macro Macro Editor Screen FigureDragging Commands into the Macro Window Macro Editor Screen with IR Command Library SelectedProgrammed IR Output Port Selector Modifying the IR Library IR Library ManagerIR Library Manager Edit Tab Editing IR Commands in the User IR LibraryReady to Align Remote and IR Learner Adding Function Names to the Function ListWaveform View Tab Internal CommandsHex View Tab Internal Command Window Time DelayTime Delay Macro Window Status TestRS-232 Macro Editor Window with an RS-232 command string RS-232 Command Outbound Serial ControlRS-232 Macro Window Repeat Steps Stop MacroControlling the C4630 SE via RS-232 Inbound Serial Control Drag Commands Into BracketToggle IR Code C4630 SE Inbound Serial Protocol fixedC4630 SE Inbound Serial Commands C4630 SE Status Queries Inbound Serial Control of C4630 SEs in Multi-Unit SystemsSerial Commands Simulate Button Press Commands in Multi-Unit SystemsPowering K2 Keypads Wiring K2 and K1 Keypad ConnectionsC4630 SE Extra Command Macros Expanded Control FeaturesProgramming a K2 Button to Trigger a C4630 SE Extra Command Triggering C4630 SE Extra Command Macros From the K1 and K2Generating a System Configuration Report Getting System Configuration InformationSystem Configuration Report Showing RS-232 Macro Commands Finding RS-232 Commands in MacrosAudio Performance SpecificationsProblem Solution TroubleshootingAudio Infrared Control Problem Important Freight collect shipments will be refused Technical Assistance and ServiceExclusions and Limitations Limited Warranty Coverage U.S.A. OnlySystem Notes Page 33-4119 07/07