Sonance Keypad Backlighting Jumper, C4630 SE Keypad Connections, Connecting the IR Receiver

Page 20
Figure 19:C4630 SE Keypad
Controller Ports

 

 

C4630 SE HOME AUDIO SYSTEM

3. Connect the IR receiver’s 3-conductor ribbon cable to the keypad’s rear-

 

 

 

 

panel IR RECEIVER CONNECTION as shown in Figure 16. The connection

 

 

 

 

features a 3-pin removable connector similar to the ones used for the

 

 

 

FROM IR

speaker connectors. Insert the wires into the openings at the rear of the

 

 

 

 

 

 

RECEIVER

connector and secure them by tightening the screws at the top of the

 

 

 

GROUND

connector.

 

 

 

 

 

 

 

 

+12V (center)

 

 

 

 

 

• The gray wire on the ribbon cable is the DATA wire, the center wire is

 

 

 

IR DATA (white)

+12V and the remaining wire is GROUND.

 

 

 

 

 

Keypad Backlighting Jumper

 

 

 

 

 

The C4630 SE Main and Numeric Keypads have rear-panel Backlight

 

 

PIN 14

 

 

 

NUMBERICKEYPAD

 

Jumpers (Figure 17) that allow you to adjust the amount

of keypad

C4630

 

 

backlighting to suit room lighting conditions and user preference.

MAIN

 

FOR

 

KEYPAD

 

 

 

 

RESERVED

Figure 16:

Position 1 = DIM; Position 2 = BRIGHT; remove the jumper

to turn the

 

PIN 1

backlight OFF.

 

1

2

 

Connecting the IR Receiver

 

 

 

 

to the Keypad

Using needle-nose pliers, tweezers or a similar tool, carefully insert the

 

 

 

 

 

 

 

jumper in the desired position (see Figure 17). The factory default is

 

 

 

 

BRIGHT.

 

 

 

 

 

NOTE: Unless the backlight jumper is removed, the keypad backlighting

 

 

 

is always ON, even if the local zone and all zones are OFF.

1 2

1 2

1 2

C4630 SE Keypad Connections

DIM

BRIGHT

OFF

Figure 17: C4630 SE Keypad

1. In direct runs from keypad to controller, pull a length of CAT5 wire from every key-

Backlight Jumper

pad mounting location to the C4630 SE location. The maximum length of any single

 

 

 

 

 

 

CAT5 cable is 1000’.

 

 

 

2.Terminate each CAT5 cable with RJ45 connectors on each end. Follow the TIA 568B wiring standard (see Figure 18).

3.We strongly recommend testing your connections with an RJ45 network cable tester to check for cable continuity, miswiring, open connections, shorted connections or cross-pinning.

4.Connect the CAT5/RJ45 cable to the RJ45 Connection Jack on the back of the Main Keypad (see Figure 14, on page

18)and to the zone’s Keypad

Controller Port on the C4630 SE

RJ45 Connector

TIA 568B

 

Z

Z

(see Figure 19).

(Flat Side UP)

Wiring Standard

 

 

 

 

PIN

COLOR

SIGNAL

O

O

 

 

 

 

1

White/Orange

No Signal

N

N

 

 

 

 

 

2

Orange

No Signal

E

E

 

 

 

 

 

 

 

 

 

3

White/Green

No Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Blue

IR Data

1

2

 

 

 

 

 

 

 

 

 

5

White/Blue

Status

 

 

 

 

 

 

 

 

 

6

Green

No Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

7

White/Brown

Ground

 

 

 

 

 

 

 

 

 

 

 

 

8

Brown

+12V DC

 

 

 

 

 

 

 

 

 

 

 

 

Figure 18:

Keypad Connection RJ45 Pinout

20

Image 20
Contents C4630 SE Page Important Safety Information Ance to Rain or MOISTURE.Table of Contents C4630 SE Home Audio System C4630 SE Features IntroductionAudio ControlUnpacking Box ContentsPlacement System Overview Shelf-MountingRack-Mounting Control ConsiderationsC4630 SE Home Audio System C4630 SE Front Rear Panels Rear PanelConnecting the C4630 SE Power ConnectionsReplacing the AC Fuse Audio Source ConnectionsUse Good Speaker Wire Wiring the Speaker ConnectorsSource Output Connections Speaker ConnectionsLine Output Fixed/Variable Switch Connecting a High-Power Amplifier in a ZoneUsing a Multi-Channel Amplifier for Sub-Zone Expansion Zone Line Output ConnectionsUsing a High-Power Amplifier in a Zone C4630 SEWhen using three or more C4630 SE Controllers, use mini IR Connections see FigurePlug Y-adaptors on the IR Link jack on the Primary C4630 SE To connect to the IR Link jacks of the Secondary C4630 SEsWiring the Control Connections Control Out TerminalSync Connections Control Input/ Output Sync ConnectionsRS-232 Terminal Pins Connector Side Paging Connections see FigureRS-232 Connection see Figure RS-232C4630 SE Main and Numeric Keypads C4630 SE Keypad ControllersC4630 SE Main Keypad see Figure Installing an IR Receiver into the Keypad C4630 SE Numeric Keypad see , onKeypad Location Main Keypad IR Receiver HolsterConnecting the IR Receiver Keypad Backlighting JumperC4630 SE Keypad Connections To the KeypadKeypad Ribbon Cable External Keypad Power see FigureMounting the C4630 SE Keypads Into Openings Changing the Main Keypad Source ButtonsInsert Tool Optional C4630 SE IR Remote Control C4630 SE Out-Of-The-Box FunctionsFront Panel Controls and Indicators ALL OFF SwitchInstalling the Sonance Control Manager Software Sonance Control Manager SoftwareTransferring System Information to the C4630 SE To transfer programming to the C4630 SEUpdating the Sonance Control Manager Software and Firmware Upgrading Sonance Control Manager SoftwareUpgrade Firmware Warning Screen Upgrading the C4630 SE FirmwareCreating a New C4630 SE System Device ScreenRenaming C4630 SEs in a System with Multiple Units Setting Up a Zone To cor rect for too low or too high a level Feedback , etcBBE Sound Enhancement Setting Up SourcesRear-Panel BBE ON/OFF Switches General Macro Programming Notes Programming C4630 SE Keypad MacrosDevice Screen Figure Building Macros Fi g u re 4 2 Z o n e 1 P ro g r a m m i n g S c re e nMacro Command Types Command From Library IR CommandsAdding an IR Command to a Macro Macro Editor Screen FigureProgrammed IR Output Port Selector Macro Editor Screen with IR Command Library SelectedDragging Commands into the Macro Window IR Library Manager Modifying the IR LibraryEditing IR Commands in the User IR Library IR Library Manager Edit TabAdding Function Names to the Function List Ready to Align Remote and IR LearnerHex View Tab Internal CommandsWaveform View Tab Time Delay Internal Command WindowTime Delay Macro Window Status TestRS-232 Macro Window RS-232 Command Outbound Serial ControlRS-232 Macro Editor Window with an RS-232 command string Stop Macro Repeat StepsDrag Commands Into Bracket Controlling the C4630 SE via RS-232 Inbound Serial ControlToggle IR Code C4630 SE Inbound Serial Protocol fixedC4630 SE Inbound Serial Commands Inbound Serial Control of C4630 SEs in Multi-Unit Systems C4630 SE Status QueriesSimulate Button Press Commands in Multi-Unit Systems Serial CommandsWiring K2 and K1 Keypad Connections Powering K2 KeypadsExpanded Control Features C4630 SE Extra Command MacrosTriggering C4630 SE Extra Command Macros From the K1 and K2 Programming a K2 Button to Trigger a C4630 SE Extra CommandGetting System Configuration Information Generating a System Configuration ReportFinding RS-232 Commands in Macros System Configuration Report Showing RS-232 Macro CommandsSpecifications Audio PerformanceTroubleshooting Problem SolutionAudio Infrared Control Problem Technical Assistance and Service Important Freight collect shipments will be refusedLimited Warranty Coverage U.S.A. Only Exclusions and LimitationsSystem Notes Page 33-4119 07/07