Each C4630 SE inbound serial command begins with a colon character (:), followed by a single letter that indicates the desired command, then one or more parameters, and ends with a carriage return (<cr>).

Command

Syntax

Parameters

State

Comments

Zone Power

:Zxy<cr>

x = Zone 1 – 6; y = State

1=On; 0=Off

Discrete Zone Setting

All Zones Off

:Zy<cr>

y = State

1=On; 0=Off

Global Setting Only

Source Select

:Sxy<cr>

x = Zone 1 – 6; y = Source 1 – 4

Adjustable

Discrete Zone Setting

Volume

:Vxyy<cr>

x = Zone 1 – 6; yy = Vol 0 – 60

Adjustable

Discrete Zone Setting

Volume Step

:Vx++<cr>

++ = increase 1 step

Adjustable

Discrete Zone Setting

 

:Vx--<cr>

-- = decrease 1 step

Adjustable

Discrete Zone Setting

Page Volume

:Gxyy<cr>

x = Zone 1 – 6; yy = Vol 0 – 60

Adjustable

Discrete Zone Setting

Page Volume Step

:Gx++<cr>

++ = increase 1 step

Adjustable

Discrete Zone Setting

 

:Gx--<cr>

-- = decrease 1 step

Adjustable

Discrete Zone Setting

Mute

:Mxy<cr>

x = Zone 1 – 6; y = State

1 = Mute On; 0 = Mute Off

Discrete Zone Setting

Balance

:Bxyyy<cr>

x = Zone 1 – 6; yyy = Bal -10 – +10

Adjustable; Center = 0

Discrete Zone Setting

Balance Bump Step

:Bx++<cr>

++ = increase 1 step to right

Adjustable

Discrete Zone Setting

 

:Bx--<cr>

-- = increase 1 step to left

Adjustable

Discrete Zone Setting

Bass

:Lxyy<cr>

x = Zone 1 – 6 yy = Bass -8 – +8

Adjustable; Flat = 0

Discrete Zone Setting

Bass Bump Step

:Lx++<cr>

++ = increase 1 step

Adjustable

Discrete Zone Setting

 

:Lx--<cr>

-- = decrease 1 step

Adjustable

Discrete Zone Setting

Treble

:Hxyy<cr>

x = Zone 1 – 6; yy = Treble -8 – +8

Adjustable; Flat = 0

Discrete Zone Setting

Treble Bump Step

:Hx++<cr>

++ = increase 1 step

Adjustable

Discrete Zone Setting

 

:Hx--<cr>

-- = decrease 1 step

Adjustable

Discrete Zone Setting

Simulate Button Press

:Pzxyyy<cr>

See S I M U L A T E B U T T O N P R E S S C O M M A N D S on page 45

 

After each command is received the C4630 SE will respond with ‘+OK’ if the command is recognized and executed, or ‘+ERR’ if the command is invalid. Note that even valid commands will return ‘+ERR’ if the C4630 SE is not able to process them (i.e. if it is turned OFF).

43

Image 43
Contents C4630 SE Page Ance to Rain or MOISTURE. Important Safety InformationTable of Contents C4630 SE Home Audio System Control C4630 SE FeaturesIntroduction AudioPlacement Box ContentsUnpacking Control Considerations System OverviewShelf-Mounting Rack-MountingC4630 SE Home Audio System Rear Panel C4630 SE Front Rear PanelsAudio Source Connections Connecting the C4630 SEPower Connections Replacing the AC FuseSpeaker Connections Use Good Speaker WireWiring the Speaker Connectors Source Output ConnectionsZone Line Output Connections Line Output Fixed/Variable SwitchConnecting a High-Power Amplifier in a Zone Using a Multi-Channel Amplifier for Sub-Zone ExpansionC4630 SE Using a High-Power Amplifier in a ZoneTo connect to the IR Link jacks of the Secondary C4630 SEs When using three or more C4630 SE Controllers, use miniIR Connections see Figure Plug Y-adaptors on the IR Link jack on the Primary C4630 SEControl Input/ Output Sync Connections Wiring the Control ConnectionsControl Out Terminal Sync ConnectionsRS-232 RS-232 Terminal Pins Connector SidePaging Connections see Figure RS-232 Connection see FigureC4630 SE Main Keypad see Figure C4630 SE Keypad ControllersC4630 SE Main and Numeric Keypads Main Keypad IR Receiver Holster Installing an IR Receiver into the KeypadC4630 SE Numeric Keypad see , on Keypad LocationTo the Keypad Connecting the IR ReceiverKeypad Backlighting Jumper C4630 SE Keypad ConnectionsMounting the C4630 SE Keypads External Keypad Power see FigureKeypad Ribbon Cable Insert Tool Changing the Main Keypad Source ButtonsInto Openings C4630 SE Out-Of-The-Box Functions Optional C4630 SE IR Remote ControlSonance Control Manager Software Front Panel Controls and IndicatorsALL OFF Switch Installing the Sonance Control Manager SoftwareUpgrading Sonance Control Manager Software Transferring System Information to the C4630 SETo transfer programming to the C4630 SE Updating the Sonance Control Manager Software and FirmwareUpgrading the C4630 SE Firmware Upgrade Firmware Warning ScreenDevice Screen Creating a New C4630 SE SystemRenaming C4630 SEs in a System with Multiple Units To cor rect for too low or too high a level Feedback , etc Setting Up a ZoneRear-Panel BBE ON/OFF Switches Setting Up SourcesBBE Sound Enhancement Device Screen Figure Programming C4630 SE Keypad MacrosGeneral Macro Programming Notes Fi g u re 4 2 Z o n e 1 P ro g r a m m i n g S c re e n Building MacrosMacro Editor Screen Figure Macro Command TypesCommand From Library IR Commands Adding an IR Command to a MacroDragging Commands into the Macro Window Macro Editor Screen with IR Command Library SelectedProgrammed IR Output Port Selector Modifying the IR Library IR Library ManagerIR Library Manager Edit Tab Editing IR Commands in the User IR LibraryReady to Align Remote and IR Learner Adding Function Names to the Function ListWaveform View Tab Internal CommandsHex View Tab Status Test Time DelayInternal Command Window Time Delay Macro WindowRS-232 Macro Editor Window with an RS-232 command string RS-232 Command Outbound Serial ControlRS-232 Macro Window Repeat Steps Stop MacroC4630 SE Inbound Serial Protocol fixed Drag Commands Into BracketControlling the C4630 SE via RS-232 Inbound Serial Control Toggle IR CodeC4630 SE Inbound Serial Commands C4630 SE Status Queries Inbound Serial Control of C4630 SEs in Multi-Unit SystemsSerial Commands Simulate Button Press Commands in Multi-Unit SystemsPowering K2 Keypads Wiring K2 and K1 Keypad ConnectionsC4630 SE Extra Command Macros Expanded Control FeaturesProgramming a K2 Button to Trigger a C4630 SE Extra Command Triggering C4630 SE Extra Command Macros From the K1 and K2Generating a System Configuration Report Getting System Configuration InformationSystem Configuration Report Showing RS-232 Macro Commands Finding RS-232 Commands in MacrosAudio Performance SpecificationsProblem Solution TroubleshootingAudio Infrared Control Problem Important Freight collect shipments will be refused Technical Assistance and ServiceExclusions and Limitations Limited Warranty Coverage U.S.A. OnlySystem Notes Page 33-4119 07/07