IMPORTANT: your Kenmore Natural Gas Grill can- not be converted to use LP Gas. Attempting to do so is extremely hazardous and wilt also void the grill warranty.
Figure 1 (Natural gas model only)
GAS SUPPLY
_'_INSIDE
_'_WALL
OUTSIDE
Your natural gas grill is designed to operate on natural gas only, at a pressure of 7" water column (W.C.) (1/4 psi or 1.75 kpa), regulated at the residential meter. Check with your gas utility company for local gas pressure and with your local municipality for building code requirements.
If your residential gas line pressure has not been regulated to 7" W.C., contact your local gas utility company for professional assistance.
It is recommended that a Shutoff Valve be installed at the gas supply source outdoors. Install at a point after the gas pipe exits the outside wall and before the
See Fig. 1.
•Pipe sealing compound or pipe thread tape resis- tant to the action of natural gas must be used on all male pipe threads when making the connection.
Disconnect your gas grill from fuel source when the gas supply is being tested at high pressures. This gas grill and its individual shutoff valve must be disconnected from the gas supply pipe system during any pressure testing of that system at pressure in excess of 1/2 psi (3.5kpa).
WALL
TO GRILL
LOCKING | SHUT OFF |
SHUT OFF |
|
MALE _.
FITTING
J
QUICK
DISCONNECT
Turno_ | gnlwhen_e gassupp@_ |
bei%g_s_d atbw p_sstm_s.The gm]hnustl_ 9o_=d f_m _e gassupp]fp_esks_m by
cbsi | anualshum vadrde |
anypm_su_ _stflgof_e gas supp]/p_e atp_ssm£s equal_Dor]_ssfizgn1/2psi
S a).