Metrologic Instruments MS7220 manual Installation for Keyboard Wedge Interface

Page 10

INSTALLATION FOR KEYBOARD WEDGE INTERFACE

1.Follow the “Getting Started” steps on page 3.

2.Turn of the host system.

3.Disconnect the keyboard from the host.

4.Connect the PowerLink cable to the jack labeled “Keyboard Wedge ” on the MS7220.

5.Connect the “Y” end of the PowerLink cable to the keyboard and the keyboard port on the host. If

necessary use the male/female

Keyboard Wedge

adapter cable supplied with the

 

scanner for proper connections.

 

Before continuing verify that the

 

powerlink cable is connected to the

 

proper communication jack on the

 

scanner. Incorrect cable connection

 

can cause communication problems

 

or potential damage to the scanner.

 

6.Connect the external power supply to the power jack on the PowerLink cable.

7.Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet.

8.Connect AC power to the transformer. The outlet should be

near the equipment and easily

Figure 3: Keyboard Wedge Interfaces

accessible.

 

9.Slide the cable cover into place on the back of the scanner then secure it with the three M3 screws provided.

10.Turn on the host system.

11.Scan the bar code below to configure the MS7220 for Keyboard Wedge

communication.

Load Keyboard Wedge Defaults

³ 9 9 9 9 9 4

Caution:

To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950.

To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.

7

Image 10
Contents Metrologic INSTRUMENTS, INC Locations North AmericaTable of Contents Introduction Stand Alone Keyboard Wedge Powerlink Cable Mlpn Scanner and AccessoriesMetroSelect Programming Guide** Mlpn 00-02407 or Stand Getting Started Getting Started Installation for Ocia Interface To power the unit with an external power supplyTo power the unit from the host device Manufacturers NoteInstallation for Keyboard Wedge Interface Keyboard Wedge InterfacesInstallation for STAND-ALONE Keyboard Interface Stand-Alone Keyboard InterfaceInstallation for RS232 or Light PEN Interfaces Turn on the host systemFor RS232 Communication Installation of AN Auxiliary Scanner Master/Slave Setup Scanner Parts Scanner PartsMULTI-FUNCTION Button Multi-Function ButtonOne Beep Audible IndicatorsThree Beeps on power up Razzberry ToneFlashing Red and Green and Two Razzberry Tones Failure ModesFlashing Green and One Razzberry Tone Continuous Razzberry Tone with both LEDs offVisual Indicators Maintenance LabelsDepth of Field Specifications Top View of Depth of FieldDepth of Field by Minimum BAR Code Element Width MilsSide View of Depth of Field Troubleshooting Guide MS7220 Series Troubleshooting GuideCodes. The scanner Keyboard Wedge Only RS-232 Only Slave operation With any interface RS232 Demonstration Program Keyboard Type Applications and ProtocolsKeyboard Country Type Design Specifications EMC Default Settings IBM KBWUPC-E Default Settings XON/XOFF Default Settings Default settings for Aux interface MS7220 Stands Vertical Stand Installation Mlpn Optional Flexible Stand Installation Mlpn MS7220-12 Keyboard Wedge Stand-Keyboard Scanner and Cable TerminationsMS7220-12 MS7220-12 RS-232 or Light PenPin male mini-DIN connector to the PC Pin D-type female connector to the PCMS7220 Auxilary Port RS232 in Only Cable Connector Configuration Limited Warranty Corporate HeadquartersRemarque Patents European StandardIndex LED