VISUAL INDICATORS

There is a red LED and a green LED on the front of the MS7220. When the scanner is on, the flashing or constant illumination of the LEDs indicates the status of the current scan and the scanner.

No Red or Green LED

The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer.

Steady Green

When the laser is active, the green LED is illuminated. The green LED will remain illuminated until the laser is deactivated.

During the power save mode, the laser will turn on and off. During this period, the green LED remains illuminated.

Steady Green and Single Red Flash

When the scanner successfully reads a bar code, the red LED will flash and the scanner will beep once. If the red LED does not flash or the scanner does not beep once, then the bar code has not been successfully read.

Steady Green and Steady Red

After a successful scan, the scanner transmits the data to the host device. Some communication modes require that the host inform the scanner when data is ready to be received. If the host is not ready to accept the information, the scanner’s red LED will remain on until the data can be transmitted.

Flashing Green then Flashing Red

This indicates the scanner is in program mode. A razzberry tone

indicates that an invalid bar code has been scanned in this mode.

or

If the unit is in sleep mode, each LED will flash once every 15 seconds.

Steady Red, Green off

This indicates the scanner may be waiting for communication from the host.

17

Image 20
Contents Metrologic INSTRUMENTS, INC Locations North AmericaTable of Contents Introduction MetroSelect Programming Guide** Mlpn 00-02407 or Stand Scanner and AccessoriesStand Alone Keyboard Wedge Powerlink Cable Mlpn Getting Started Getting Started Installation for Ocia Interface To power the unit with an external power supplyTo power the unit from the host device Manufacturers NoteInstallation for Keyboard Wedge Interface Keyboard Wedge InterfacesInstallation for STAND-ALONE Keyboard Interface Stand-Alone Keyboard InterfaceInstallation for RS232 or Light PEN Interfaces Turn on the host systemFor RS232 Communication Installation of AN Auxiliary Scanner Master/Slave Setup Scanner Parts Scanner PartsMULTI-FUNCTION Button Multi-Function ButtonAudible Indicators Three Beeps on power upOne Beep Razzberry ToneFailure Modes Flashing Green and One Razzberry ToneFlashing Red and Green and Two Razzberry Tones Continuous Razzberry Tone with both LEDs offVisual Indicators Maintenance LabelsDepth of Field Specifications Top View of Depth of FieldDepth of Field by Minimum BAR Code Element Width MilsSide View of Depth of Field Troubleshooting Guide MS7220 Series Troubleshooting GuideCodes. The scanner Keyboard Wedge Only RS-232 Only Slave operation With any interface RS232 Demonstration Program Keyboard Country Type Applications and ProtocolsKeyboard Type Design Specifications EMC Default Settings IBM KBWUPC-E Default Settings XON/XOFF Default Settings Default settings for Aux interface MS7220 Stands Vertical Stand Installation Mlpn Optional Flexible Stand Installation Mlpn Scanner and Cable Terminations MS7220-12MS7220-12 Keyboard Wedge Stand-Keyboard MS7220-12 RS-232 or Light PenMS7220 Auxilary Port RS232 in Only Pin D-type female connector to the PCPin male mini-DIN connector to the PC Cable Connector Configuration Limited Warranty Corporate HeadquartersRemarque Patents European StandardIndex LED